欢迎访问ic37.com |
会员登录 免费注册
发布采购

MAX308CSE 参数 Datasheet PDF下载

MAX308CSE图片预览
型号: MAX308CSE
PDF下载: 下载PDF文件 查看货源
内容描述: 高精度, 8通道/双4通道,高性能, CMOS模拟多路复用器 [Precision, 8-Channel/Dual 4-Channel, High-Performance, CMOS Analog Multiplexers]
分类和应用: 复用器开关复用器或开关信号电路光电二极管
文件页数/大小: 12 页 / 125 K
品牌: MAXIM [ MAXIM INTEGRATED PRODUCTS ]
 浏览型号MAX308CSE的Datasheet PDF文件第2页浏览型号MAX308CSE的Datasheet PDF文件第3页浏览型号MAX308CSE的Datasheet PDF文件第4页浏览型号MAX308CSE的Datasheet PDF文件第5页浏览型号MAX308CSE的Datasheet PDF文件第7页浏览型号MAX308CSE的Datasheet PDF文件第8页浏览型号MAX308CSE的Datasheet PDF文件第9页浏览型号MAX308CSE的Datasheet PDF文件第10页  
Precision, 8-Channel/Dual 4-Channel,
High-Performance, CMOS Analog Multiplexers
MAX308/MAX309
______________________________________________________________Pin Description
PIN
MAX308
1, 15, 16
2
3
4–7
8
9–12
13
14
MAX309
1, 16
2
3
4–7
8, 9
10–13
14
15
NAME
A0, A2, A1
A0, A1
EN
V-
NO1–NO4
NO1A–NO4A
COM
COMA, COMB
NO8–NO5
NO4B–NO1B
V+
GND
Address Inputs
Address Inputs
Enable Input
Negative Supply Voltage Input
Analog Inputs—bidirectional
Analog Inputs—bidirectional
Analog Output—bidirectional
Analog Outputs—bidirectional
Analog Inputs—bidirectional
Analog Inputs—bidirectional
Positive Supply Voltage Input
Ground
FUNCTION
__________Applications Information
V+
Operation with
Supply Voltages Other than 15V
Using supply voltages less than ±15V will reduce the
analog signal range. The MAX308/MAX309 switches
operate with ±4.5V to ±20V bipolar supplies or with a
+4.5V to +30V single supply. Connect V- to GND when
operating with a single supply. Both device types can
also operate with unbalanced supplies, such as +24V
and -5V. The
Typical Operating Characteristics
graphs
show typical on-resistance with 20V, 15V, 10V, and 5V
supplies. (Switching times increase by a factor of two
or more for operation at 5V.)
NO
COM
V
g
Overvoltage Protection
Proper power-supply sequencing is recommended for
all CMOS devices. Do not exceed the absolute maxi-
mum ratings, because stresses beyond the listed rat-
ings may cause permanent damage to the devices.
Always sequence V+ on first, then V-, followed by the
logic inputs, NO, or COM. If power-supply sequencing
is not possible, add two small signal diodes in series
with supply pins for overvoltage protection (Figure 1).
Adding diodes reduces the analog signal range to 1V
below V+ and 1V above V-, but does not affect the
devices’ low switch resistance and low leakage charac-
teristics. Device operation is unchanged, and the differ-
ence between V+ and V- should not exceed +44V.
6
V-
Figure 1. Overvoltage Protection Using External Blocking
Diodes
_______________________________________________________________________________________