MAX200–MAX209/
MAX211/MAX213
Electrical Characteristics (continued)
+5V, RS-232 Transceivers
with 0.1μF External Capacitors
CC
= +5V ±10%; MAX200/MAX203/MAX205/MAX207: V
CC
= +5V ±5%,
C1–C4 = 0.1µF; MAX201/MAX209: V
CC
= +5V ±10%, V+ = +9.0V to +13.2V, T
A
= T
MIN
to T
MAX
, unless otherwise noted.)
PARAMETER
Receiver Input Threshold
Low
Receiver Input Threshold
High
RS-232 Input Hysteresis
RS-232 Input Resistance
TTL/CMOS Output-Voltage
Low
TTL/CMOS Output-Voltage
High
TTL/CMOS Output
Leakage Current
Output Enable Time
Output Disable Time
Receiver Propagation
Delay
Transmitter Output
Resistance
Transition Region Slew
Rate
RS-232 Output Short-
Circuit Current
Maximum Data Rate
R
L
= 3kΩ to 7kΩ, C
L
= 50pF to 1000pF, one transmitter
120
V
CC
= +5V,
T
A
= +25°C
V
CC
= +5V,
T
A
= +25°C
V
CC
= +5V, T
A
= +25°C
I
OUT
= 3.2mA
I
OUT
= 1.6mA
I
OUT
= 1.0mA
EN
= V
CC
, EN = 0V, 0 ≤ R
OUT
≤ V
CC
Figure 2
Figure 2
SHDN
= 0V, R4, R5
SHDN
= V
CC
MAX200–MAX211
V
CC
= V+ = V- = 0V, V
OUT
= ±2V
C
L
= 50pF to 2500pF,
R
L
= 3kΩ to 7kΩ,
V
CC
= 5V, T
A
= +25°C
measured from +3V to
-3V or -3V to +3V
MAX200, MAX202–MAX211, MAX213
MAX201
300
3
5.5
4
±10
30
V/µs
30
±60
mA
kbps
MAX205, MAX206, MAX209, MAX211,
MAX213
MAX205, MAX206, MAX209, MAX211,
MAX213
MAX213
CONDITIONS
Active mode
Shutdown mode, MAX213, R4, R5
Active mode
Shutdown mode, MAX213, R4, R5
0.2
3
MIN
0.8
0.6
TYP
1.2
1.5
1.7
1.5
0.5
5
2.4
2.4
1.0
7
0.4
3.5
0.05
600
200
4
0.5
0.5
40
10
10
Ω
µs
±10
MAX
UNITS
V
V
V
kΩ
V
V
µA
ns
ns
V
CC
= +5V, no hysteresis in shutdown
MAX201, MAX202, MAX203
All others
www.maximintegrated.com
Maxim Integrated
│
3