1ꢀ5k EꢁD-ꢂrotected, +ꢀk Rꢁ-232 Transceivers  
R
1M  
R 1500Ω  
D
C
I 100%  
P
90%  
PEAK-TO-PEAK RINGING  
(NOT DRAWN TO SCALE)  
I
r
DISCHARGE  
RESISTANCE  
CHARGE-CURRENT  
LIMIT RESISTOR  
AMPERES  
HIGH-  
VOLTAGE  
DC  
DEVICE  
UNDER  
TEST  
C
s
100pF  
STORAGE  
CAPACITOR  
36.8%  
SOURCE  
10%  
0
TIME  
0
t
RL  
t
DL  
CURRENT WAVEFORM  
Figure 6b. Human Body Model Current Waveform  
Figure 6a. Human Body ESD Test Model  
I
R
50M to 100M  
R 330Ω  
D
C
100%  
90%  
DISCHARGE  
RESISTANCE  
CHARGE CURRENT  
LIMIT RESISTOR  
HIGH-  
VOLTAGE  
DC  
DEVICE  
UNDER  
TEST  
C
s
150pF  
STORAGE  
CAPACITOR  
SOURCE  
10%  
Figure 7a. IEC1000-4-2 ESD Test Model  
t
t = 0.7ns to 1ns  
r
30ns  
60ns  
IEC1000-4-2  
The IEC1000-4-2 standard covers ESD testing and  
performance of finished equipmentꢁ it does not  
specifically refer to integrated circuits. The  
MAX202E/MAX203E–MAX213E, MAX232E/MAX241E  
help you design equipment that meets level 4 (the  
highest level) of IEC1000-4-2, without the need for  
additional ESD-protection components.  
Figure 7b. IEC1000-4-2 ESD Generator Current Waveform  
The air-gap test involves approaching the device with a  
charged probe. The contact-discharge method  
connects the probe to the device before the probe is  
energized.  
Machine Model  
The Machine Model for ESD tests all pins using a  
200pF storage capacitor and zero discharge  
resistance. Its objective is to emulate the stress caused  
by contact that occurs with handling and assembly  
during manufacturing. Of course, all pins require this  
protection during manufacturing, not just RS-232 inputs  
and outputs. Therefore, after PC board assembly, the  
Machine Model is less relevant to I/O ports.  
The major difference between tests done using the  
Human Body Model and IEC1000-4-2 is higher pea5  
current in IEC1000-4-2, because series resistance is  
lower in the IEC1000-4-2 model. Hence, the ESD  
withstand voltage measured to IEC1000-4-2 is  
generally lower than that measured using the Human  
Body Model. Figure 7b shows the current waveform for  
the 85V IEC1000-4-2 level-four ESD contact-discharge  
test.  
12 ______________________________________________________________________________________