Low-Cost, Multichemistry Battery-
Charger Building Block
Typical Operating Characteristics
(Circuit of Figure 1a, V
= 20V, T = +25°C, unless otherwise noted.)
A
DCIN
LOAD-TRANSIENT RESPONSE
LOAD-TRANSIENT RESPONSE
(STEP-IN LOAD CURRENT)
(BATTERY REMOVAL AND REINSERTION)
MAX1772 toc01
MAX1772 toc02
CCS
V
BATT
20V/div
CCI
500mV/div
CCI
CCS
I
BATT
500mV/div
2A/div
CCV
CCI
V
BATT
20V/div
CCI
I
LOAD
2A/div
500mV/div
CCV
500mV/div
1ms/div
1ms/div
BATTERY PRESENT
ICTL = 3.30V
CHARGING CURRENT = 2.0A
= 16V
ICTL = 0.957V
VCTL = 3.3V
V
BATT
LOAD STEP = 0 TO 3A
I
LIMIT = 5A
SOURCE
LDO LOAD REGULATION
LINE-TRANSIENT RESPONSE
MAX1772 toc03
0.4
0.3
0.2
0.1
0
VCTL = 0
DCIN
ICTL = 3.3V
DCIN = 20.0V
LDO = 5.40V
10V/div
V
BATT
(AC-COUPLED)
-0.1
-0.2
-0.3
-0.4
100mV/div
0
1
2
3
4
5
6
7
8
9
10
2ms/div
LDO CURRENT (mA)
V
= 16V
BATT
DCIN = 18.5V TO 27.5V
= 150mA
I
LOAD
_______________________________________________________________________________________
7