Multichannel Remote/Local
Temperature Sensors
A
B
C
D
E
F
G
H
I
J
K
t
t
HIGH
LOW
SMBCLK
SMBDATA
t
t
t
t
t
BUF
SU:STA HD:STA
SU:DAT
SU:STO
A = START CONDITION
E = SLAVE PULLS SMBDATA LINE LOW
I = ACKNOWLEDGE CLOCK PULSE
J = STOP CONDITION
K = NEW START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
Figure 4. SMBus Read Timing Diagram
A
B
C
D
E
F
G
H
I
J
K
L
M
t
t
HIGH
LOW
SMBCLK
SMBDATA
t
t
t
t
HD:DAT
HD:STA
SU:STA
SU:DAT
t
t
SU:STO
BUF
A = START CONDITION
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = SLAVE PULLS SMBDATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO MASTER
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION, DATA EXECUTED BY SLAVE
M = NEW START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
Figure 5. SMBus Write Timing Diagram
Table 8. Slave Address Decoding (ADD0
and ADD1)
ADD0
ADD1
ADDRESS
0011 000
0011 001
0011 010
0101 001
0101 010
0101 011
1001 100
1001 101
1001 110
GND
GND
GND
High-Z
GND
V
CC
High-Z
High-Z
High-Z
GND
High-Z
V
CC
V
CC
V
CC
V
CC
GND
High-Z
V
CC
Note: High-Z means that the pin is left unconnected and floating.
______________________________________________________________________________________ 15