Re m o t e /Lo c a l Te m p e ra t u re S e n s o r
w it h S MBu s S e ria l In t e rfa c e
MX617A
A
B
C
D
E
F
G
H
I
J
K
L
M
t
t
HIGH
LOW
SMBCLK
SMBDATA
t
t
t
t
HD:DAT
HD:STA
SU:STA
SU:DAT
t
t
SU:STO
BUF
A = START CONDITION
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = SLAVE PULLS SMBDATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO MASTER
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION, DATA EXECUTED BY SLAVE
M = NEW START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
Figure 4. SMBus Write Timing Diagram
A
B
C
D
E
F
G
H
I
J
K
t
t
HIGH
LOW
SMBCLK
SMBDATA
t
t
t
t
t
BUF
SU:STA HD:STA
SU:DAT
SU:STO
A = START CONDITION
E = SLAVE PULLS SMBDATA LINE LOW
I = ACKNOWLEDGE CLOCK PULSE
J = STOP CONDITION
K = NEW START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
Figure 5. SMBus Read Timing Diagram
______________________________________________________________________________________ 15