78M6610+LMU Data Sheet  
Fundamental and Harmonic Calculations  
The 78M6610+LMU includes the ability to separate low-rate voltage, current, active power, and reactive  
power measurement results into fundamental and total harmonic components. These outputs can also be  
used to track individual harmonics as well as the total value excluding the selected harmonic.  
Register  
Description  
Time Scale  
SINE  
COSINE  
Instantaneous voltage of the internal waveform generator  
1 sample  
VFUND_A  
VFUND_B  
Voltage content at specified harmonic  
IFUND_A  
IFUND_B  
Current content at specified harmonic  
PFUND_A  
PFUND_B  
Active Power content at specified harmonic  
Reactive Power content at specified harmonic  
Voltage content not at specified harmonic  
Current content not at specified harmonic  
Active Power content not at specified harmonic  
Reactive Power content not at specified harmonic  
QFUND_A  
QFUND_B  
1 interval  
VHARM_A  
VHARM_B  
IHARM_A  
IHARM_B  
PHARM_A  
PHARM_B  
QHARM_A  
QHARM_B  
The HARM register is used to select the single harmonic to extract. This input register is set by default to  
0x000001 selecting the first harmonic (also known as the fundamental frequency). This setting provides  
the user with fundamental result and the total harmonic distortion (THD) of the harmonics  
By setting the value in the HARM register to a higher harmonic, the fundamental result registers will  
contain measurement results of the selected harmonic. Likewise, by setting the value in the HARM  
register to a higher harmonic, the harmonics result registers will report the measurement of the remaining  
harmonics. As an example, for any given accumulation interval, the magnitude of measurement result  
IA_RMS would be the sum of IFUND_A and IHARM_A.  
The SINE and COSINE registers are high-rate registers updated every sample with the instantaneous  
value of the respective outputs from the internal Sine/Cosine generator. The referenced AC voltage  
frequency serves as the reference for the internal waveform generator.  
33  
Rev 0  
 