MCP795WXX/MCP795BXX
8.0
POWER-DOWN TIME-STAMP REGISTERS
Note:
It is strongly recommended that the timesaver function only be used when the oscillator is running. This
will ensure accurate functionality.
REGISTER 8-1:
MINUTES 0X18
RW
U
RW
10 Minutes
Minutes
bit 7
bit 6
bit 4 bit 3
bit 0
Legend: R = Readable Bit W = Writable Bit U = Unimplemented bit, Read as ‘0’
bit 7
Unimplemented
bit 6-4 10 Minutes
bit 3-0 Minutes
REGISTER 8-2:
HOUR 0X19
RW RW
U
RW
RW
12/24
10 Hour
AM/PM
10 Hours
Hour
bit 7
bit 6
bit 5
bit 4
bit 3
bit 0
Legend: R = Readable Bit W = Writable Bit U = Unimplemented bit, Read as ‘0’
bit 7
bit 6
bit 5
bit 4
Unimplemented
12/24 (this is a copy of the status of the bit in register 0x03:6 at the time of the event)
10 Hour AM/PM
10 Hour
bit 3-0 Hour
REGISTER 8-3:
DATE 0X1A
RW
U
U
RW
RW
10 Date
bit 4
Date
bit 7
bit 6
bit 5
bit 3
bit 0
Legend: R = Readable Bit W = Writable Bit U = Unimplemented bit, Read as ‘0’
bit 7-6 Unimplemented
bit 5-4 10 Date
bit 3-0 Date
DS22280A-page 24