DA9275.007
19 February 2004
ELECTRICAL CHARACTERISTICS
(recommended operation conditions)
Parameter
Symbol
Min
Typ
Max
Unit
Note
Frequency Range
fo
VC
VCSENS
Vout
10.00
0
36.00
VDD
MHz
V
ppm/V
Vpp
Vpp
ns
%
ms
V
1)
Voltage Control Range
Voltage Control Sensitivity
Output Voltage (10 pF, VDD 2.7 V)
Output Voltage (10 pF, VDD 5.0 V)
Rise and Fall Time (10 - 50 pF)
Output Symmetry
100
2.3
4.5
2)
Vout
10
40-60
2
Startup Time
TSTART
PD
Tri State Output Buffer
ON State
3)
4)
0
0.55
VDD
OFF State
1.6
Tri State Output Buffer
ON State
PD
V
1.6
0
VDD
0.55
OFF State
Note 1: An RS < 20 Ω crystal provides 36 MHz maximum frequency. With an RS = 70 Ω crystal the maximum
frequency is typically 20 MHz.
Note 2: VC sensitivity value depends on the crystal used. With a 30 ppm/pF crystal typical values are:
A1 > 100 ppm/V, B2 > 75 ppm/V, B3 > 60 ppm/V, C2 > 75 ppm/V, C3 > 60 ppm/V, C4 > 55 ppm/V.
Note 3: MAS9275A, MAS9275B
Note 4: MAS9275C
Note 5: If the Tri State Output Buffer is floating (i.e., PD pin not connected), the oscillator is ON in all models
(MAS9275A, -B and -C)
IC OUTLINES
OUT
X2
X1
VDD
PD
VC
VSS
MAS9275
Die map reference
12
20
µm
Note 1: MAS9275 pads are round with 80 µm diameter at opening.
Note 2: Die map reference is the actual left bottom corner of the sawn chip.
3 (10)