DA9191A.000
July 31, 1997
FUNCTIONS
Register 0EHEX (write only)
Bit
Name
State
Function
3-0
GC1[3:0]
0000-1111
Control range for GC1: -3.0dB … +3.0dB, 0.4dB/step
0000
0001
0010
-3.0dB
-2.6dB
-2.2dB
…….
1111
+3.0dB
1000
+0.2dB default value
4
5
6
7
S1
S2
S3
S4
0
1
0
1
0
1
0
1
RX
ALP
F4 output
F4 input
connected to GC1 input
connected to DEOUT
signal from S2-RXTST0-RXTST1
connected to F5 input
RBPFIN
F5 output
F5 input
connected to RBPFOUT
Register 10HEX (read only)
Bit
Name
State
Function
0
STD
0
1
0
1
DTMF tone not received
DTMF tone received
RX buffer empty
1
RXWRD
RX word received (SYS1 = 0)
Next captured byte ready (SYS1 = 1)
Transmitting previous byte or word
2
3
TXWRD
TXCOL
SATINT
reserved
0
1
0
1
0
TX buffer empty
No TX collision detected
TX collision detected
SATDET signal stable
rising or falling edge of SATDET detected
not in use
4
1
0,1
7-5
The rising edge of the signals STD, RXWRD, TXWRD, TXCOL and SATINT activates the interrupt line XINT. If the
signal(s) changes when register 10HEX or one of the other registers is read, the interrupt line will be activated right
after the register read. Reading this register sets the interrupt line inactive. If a new interrupt is generated during
register read , the interrupt line will be activated again right after register is read.
29