 浏览型号MAS6512BA1WAB05的Datasheet PDF文件第8页浏览型号MAS6512BA1WAB05的Datasheet PDF文件第9页浏览型号MAS6512BA1WAB05的Datasheet PDF文件第10页浏览型号MAS6512BA1WAB05的Datasheet PDF文件第11页浏览型号MAS6512BA1WAB05的Datasheet PDF文件第13页浏览型号MAS6512BA1WAB05的Datasheet PDF文件第14页浏览型号MAS6512BA1WAB05的Datasheet PDF文件第15页浏览型号MAS6512BA1WAB05的Datasheet PDF文件第16页  
DA6512.003  
2 December, 2016  
MEASUREMENT CONTROL REGISTER (E2/62HEX  
)
This register is used to configure and initiate a  
measurement. See table 3 below. A new conversion  
is started simply by writing 8-bit configuration data  
having SCO=1 to the measurement control register  
(E2/62HEX).  
Table 3. Measurement control register (E2/62HEX) description  
Bit Number  
Bit Name  
Description  
Value  
Function  
7-5  
OSRS  
Over Sampling Ratio  
(OSR) Selection  
000  
001  
010  
011  
0
1
0
OSR = 256  
OSR = 512  
OSR = 1024  
OSR = 2048  
4
3
TEMPREGEN  
SCO  
Temperature Mode  
Regulator Enable  
Start Conversion  
Voltage regulator disabled  
Voltage regulator enabled  
No conversion  
1
Start conversion  
External capacitive sensor  
VDD level monitoring  
Internal temperature sensor  
-
2-1  
SEL  
Capacitive/ VDD  
Monitoring /  
00  
01  
10  
11  
0
Temperature Selection  
0
XRC  
Front end function  
selector  
Ratio converter  
1
Difference converter  
The OSRS over sampling ratio selection bits  
choose between four different OSR values. High  
OSR value corresponds to high resolution but also  
The SCO Start conversion bit needs to be set 1 for  
every new measurement. It is automatically reset to  
0 after each measurement.  
longer  
conversion  
time.  
See  
Electrical  
The SEL sensor selection bits control the front-end  
multiplexer. It connects either the external  
capacitive sensor (SEL=00), VDD level monitoring  
voltage (SEL=01) or the internal temperature sensor  
(SEL=10) to the -converter.  
characteristics for further details.  
The TEMPREGEN bit enables/disables the internal  
temperature mode voltage regulator. The regulator  
need to be enabled (TEMPREGEN=1) only in  
temperature mode and it should be disabled  
(TEMPREGEN=0) in capacitance and VDD  
monitoring modes. When enabled the regulator is  
turned on during conversions and automatically  
turned off after each conversion to save power.  
Note also that if in Test register FOSC=1 and if  
TEMPREGEN=1 the regulator is forced on all the  
time even when measurement is not running.  
The XRC bit selects between two external  
capacitive sensor measurement modes. The XRC  
bit selection does not have any effect on  
temperature  
or  
VDD  
level  
monitoring  
measurements. In Ratio converter mode the output  
will be proportional to capacitance ratio (CS-CR)/CS.  
In Difference converter mode the output will be  
proportional to capacitance difference (CS-CR).  