 浏览型号MAS6505BA1WAD00的Datasheet PDF文件第6页浏览型号MAS6505BA1WAD00的Datasheet PDF文件第7页浏览型号MAS6505BA1WAD00的Datasheet PDF文件第8页浏览型号MAS6505BA1WAD00的Datasheet PDF文件第9页浏览型号MAS6505BA1WAD00的Datasheet PDF文件第11页浏览型号MAS6505BA1WAD00的Datasheet PDF文件第12页浏览型号MAS6505BA1WAD00的Datasheet PDF文件第13页浏览型号MAS6505BA1WAD00的Datasheet PDF文件第14页  
DA6505.005  
11 June 2018  
FUNCTIONAL DESCRIPTION (continued)  
Reading measurement results  
MAS6505 pressure and temperature measurement  
results are 24-bit unsigned numbers each of which  
are stored into three 8-bit result registers. The  
pressure result addresses are MSB byte (F1HEX),  
LSB byte (F2HEX) and XLSB byte (F3HEX). The  
temperature result addresses are MSB byte (F4HEX),  
LSB byte (F5HEX) and XLSB byte (F6HEX).  
MAS6505 A/D conversion and result status can be  
monitored from Status register (F0HEX) which  
contains RDYT and RDYP flags to indicate when  
there are unread temperature (T) and/or pressure  
(P) measurement results available in the pressure  
and temperature result registers. See figure 2 and  
table 7. The corresponding RDYx (x=T or P) flag is  
set (1) when a new measurement is ready for a read.  
Reading the measurement result will clear (0) the  
corresponding RDYx (x=T or P) flag.  
and/or RDYP flags) have been set high. This method  
can be used in both forced and normal modes. In  
forced mode an another choice is to wait at least  
maximum A/D conversion time before reading the  
result. See also figure 3 for Calibrated MAS6505  
sensor system measurement flow. In normal mode it  
is also possible to read results at a rate when new  
results are expected to be ready. This is possible  
since MAS6505 has internal A/D conversion result  
memory buffer. If new result is finished during read  
of result registers the new value is updated result  
registers only after the serial bus communication has  
been released. Important note: In normal mode  
the results must be always read using  
incremental read (all three bytes of each result or  
all six bytes of both results at single read sequence)  
to maintain A/D conversion data consistency. See  
table 15 example of the incremental read in chapter  
2-wire serial data interface (I2C bus). The  
incremental read is recommended to be used also in  
the forced mode.  
The decision when to read measurement results can  
be made by polling the Status register and waiting  
until the flag(s) of selected measurement(s) (RDYT  
Measurement start by setting MODE=01 or 10  
Forced mode  
temperature  
or pressure  
RDYT or RDYP  
flag set  
time  
T or P  
.
Measurement start by setting MODE=01 or 10  
Forced mode  
temperature  
and pressure  
RDYT  
flag set  
RDYP  
flag set  
T P  
x
.
time  
Measurement start by setting MODE=11  
Normal mode  
temperature  
or pressure  
RDYT or RDYP  
flag set  
RDYT or RDYP  
flag set  
DELAY setting  
T or P  
.
T or P  
.
T or P…  
DELAY setting  
time  
Measurement start by setting MODE=11  
Normal mode  
temperature  
and pressure  
RDYT  
flag set  
RDYP  
flag set  
RDYT  
flag set  
RDYP  
flag set  
DELAY setting  
T P  
x
.
T P  
x
.
time  
...  
Figure 2. Forced and normal mode measurement and status register RDYT and RDYP flag update timing  
(T=temperature, P=pressure)  
10 (44)