DA6011B.001
18 October, 2011
ABSOLUTE MAXIMUM RATINGS
All voltages with respect to ground.
Parameter
Symbol
Conditions
Min
-0.3
-0.3
-40
Max
5.5
Unit
V
Supply Voltage
VDD
Voltage range for all pins
Operating temperature
Storage Temperature
VDD+0.3
+85
V
TA
TS
oC
oC
-50
+125
Stresses beyond those listed may cause permanent damage to the device. The device may not operate under these conditions, but it will
not be destroyed.
This is a CMOS device and therefore it should be handled carefully to avoid any damage by electrostatic voltages (ESD). The most sensitive
pin for the ESD is the SOL pin.
ELECTRICAL CHARACTERISTICS: MAS6011BA1 (3V BATTERY, MCU VDDmin ≤ 2.1V)
Operating Conditions: TA = -40°C to +85°C, typical values at TA = +27°C, unless otherwise specified.
Parameter
Symbol
VDD
IDD
Conditions
Min
Typ
Max
Unit
V
Supply voltage
Current consumption
2.0
3.0
3.6
VDD=2V
VDD=3V
VDD=3.5V
30
50
60
2.40
2.10
180
85
160
200
230
2.80
2.50
600
nA
110
130
2.60
2.30
300
XPD switching level
XPD_OFF
XPD_ON
VXPD(H)
Power Down Off (XPD high)
Power Down On (XPD low)
V
XPD hysteresis
mV
V
XPD output voltage
VXPD(OUT)
VDD = 2.1 V,
IXPD = -1mA
2.0
LB switching level
LB_OFF
LB_ON
VLB(H)
Low Battery Off (LB low)
Low Battery On (LB high)
2.55
2.35
100
2.70
2.50
200
2.85
2.65
400
V
LB hysteresis
mV
V
LB output voltage
VLB(OUT)
LB high, ILB = -50 µA
LB low, ILB = +50 µA
Solar Charging Off
Solar Charging On
VDD-0.05
0.05
3.55
3.40
300
SOL switching level
SOL_OFF
SOL_ON
VSOL(H)
3.02
2.90
50
3.30
3.15
150
V
SOL hysteresis
SOL sink current
mV
mA
ISOL
VDD = 3.6 V, SOL = 0 V,
SOL switch On
19
28
43
SOL leakage current
LB_OFF – XPD_OFF
LB_ON – XPD_ON
SOL_OFF – LB_OFF
VDD = 2.9 V
-50
10
50
nA
mV
mV
mV
mV
VLB_XPD_OFF
VLB_XPD ON
VSOL_LB_OFF
VSOL_LB ON
100
200
600
650
200
300
800
949
100
200
350
SOL_ON – LB_ON
TBD = To be defined
4 (10)