欢迎访问ic37.com |
会员登录 免费注册
发布采购

605_609 参数 Datasheet PDF下载

605_609图片预览
型号: 605_609
PDF下载: 下载PDF文件 查看货源
内容描述: 点火模块 [IGNITION MODULE]
分类和应用:
文件页数/大小: 3 页 / 65 K
品牌: MALLORY [ MALLORY PERFORMANCE CLUB ]
 浏览型号605_609的Datasheet PDF文件第2页浏览型号605_609的Datasheet PDF文件第3页  
IGNITION MODULE PN 605 and PN 609
®
INSTALLATION AND ELECTRICAL WIRING PROCEDURE
PN 605/UNILITE
®
MODULE:
Apply a thin coat of silicone grease to the
bottom of the module before mounting the module to its plate in the dis-
tributor.
PN 609 and PN 605:
Slide the three wires from the MODULE, through
the grommet, to outside the distributor housing. Put the three wires from
the MODULE in the TERMINAL PIN HOUSING: GREEN WIRE in hole
#1, BROWN WIRE in hole #2, RED WIRE in hole #3. Plug the three wire
harness (PN 29349, not supplied with this kit) into the TERMINAL PIN
HOUSING.
WARNING: Make sure that the vehicle is originally equipped from
the factory with an ignition ballast resistor or loom resistance wire
from the ignition switch to the coil (+) terminal. If the vehicle is not
originally equipped from the factory with an ignition ballast resistor
or loom resistance wire, a Mallory ballast resistor, PN 700, must be
installed in series on the wire from the ignition switch to the coil (+)
terminal. See a service manual for the vehicle for further information.
For example, vehicles equipped with Ford TFI, or Delco HEI ignition
require the installation of a Mallory ballast resistor, PN 700. Failure to
use a resistor will result in the eventual destruction of the module.
A .0075" polyester gauge is provided to assist in setting the pickup gap.
Reluctor
To set pickup gap:
Loosen the two magnetic
pickup mounting nuts.
Set gap (between .007" – .010")
when a tooth on the reluctor is
pointing directly at the center of
the metal pole on the magnetic
pickup. Tighten the magnetic
pickup mounting nuts.
Connect the three wires as follows:
If a HYFIRE
®
or other aftermarket ignition control is being used, connect
the MODULE according to the instructions supplied with the HYFIRE
®
or
aftermarket ignition control.
RED WIRE:
Power/voltage for the MODULE. Connect to coil (+) terminal.
GREEN WIRE: Ignition trigger. Connect to coil (–) terminal.
BROWN WIRE: Ground for the MODULE. Connect to ENGINE BLOCK
GROUND. Clean away any grease, oil, and paint from the
mounting surface before the connection is made.
+12V FROM IGNITION SWITCH
IGNITION BALLAST RESISTOR
RED
+
COIL
NOTE—
If your vehicle is difficult to
start, remove the red wire
from the plus (+) side of the
ignition coil and connect it
to the ignition switch side of
the ballast resistor.
2
3
BROWN
GREEN
GROUND TO ENGINE BLOCK
1
NOTE—
When using a HYFIRE
®
or
other aftermarket ignition
control, connect the MODULE
according to the instructions
supplied with the HYFIRE
®
or
aftermarket ignition control.
+12V FROM IGNITION SWITCH
LOOM RESISTANCE WIRE
RED
+
COIL
2
3
BROWN
GREEN
GROUND TO ENGINE BLOCK
1
MALLORY IS A DIVISION OF THE MR. GASKET PERFORMANCE GROUP
550 MALLORY WAY, CARSON CITY, NEVADA 89701
(775) 882-6600
FAX (775) 887-4326
www.mrgasket.com
FORM 1270
(REV. C) 10/99
Made in U.S.A.