欢迎访问ic37.com |
会员登录 免费注册
发布采购

1512D24WFR 参数 Datasheet PDF下载

1512D24WFR图片预览
型号: 1512D24WFR
PDF下载: 下载PDF文件 查看货源
内容描述: 单输出和双输出DC / DC转换器 [Single and Dual Output DC/DC Converter]
分类和应用: 转换器
文件页数/大小: 3 页 / 143 K
品牌: MAKE-PS [ MAKE-PS ]
 浏览型号1512D24WFR的Datasheet PDF文件第2页浏览型号1512D24WFR的Datasheet PDF文件第3页  
www.make-ps.com  
E-mail:info@make-ps.com  
1500WFR series  
Single and Dual Output  
DC/DC Converter  
FEATUREꢀ  
15W Continuous Output Power  
Compact 1” X 2” X 0.4” Case  
Industry ꢀtandard Pin-Out  
Up to 82ꢁ Efficiency  
o
o
-25 C to +71 C Operating Temperature Range  
3
18.75W/In Power Density  
Low Cost  
INPUT CHARACTERIꢀTICꢀ  
DEꢀCRIPTIONꢀ  
Unit/Comments  
Min Typ Max  
The 1500WFR series is a family of low cost single and dual  
output 15W DC/DC converters specifically designed for space-  
critical applications. These models operate from wide (2:1)  
input voltage ranges of 18 to 36 or 36 to 72 VDC; and provide  
regulated outputs of 5, 12, 15, 12 or 15 VDC. ꢀtandard  
features include 500 VDC input/output isolation, an internal  
input filter, line/load regulation of 1.0ꢁ and a minimum switch-  
ing frequency of 190 kHz. All models are packaged in compact,  
low profile 1” X 2” X 0.4” inch metal case. This miniature size  
Input Voltage Range  
24 VDC Input Models  
48 VDC Input Models  
Input Filter  
VDC  
VDC  
Pi Networks  
18 24 36  
36 48 72  
3
yields a power density as high as 18.75 watts/in . Operation is  
o
specified over the full operating temperature range of -25 C to  
o
+71 C. Cooling is by free-air convection.  
OUTPUT CHARACTERIꢀTICꢀ  
GENERAL CHARACTERIꢀTICꢀ  
Min Typ Max Unit/Comments  
Min Typ Max Unit/Comments  
Output Voltage Accuracy  
1.0 %; Output voltage at  
nominal line & FL  
Switching Frequency  
Isolation Voltage  
Isolation Resistance  
190  
500  
kHz  
VDC, 1 minute  
Mohm, 500VDC  
Output Voltage Balance  
Dual Outputs  
Minimum Load  
Line Regulation  
Load Regulation  
Ripple/Noise  
1000  
1.0 %; Equal Output Loads  
10% of Full Load  
1
0.2 %  
1.0 %  
2
100 mV p-p, Nom.Line FL,  
20Mhz B.W. using  
1 μf bypass capacitor  
500 μS to within 1% error  
band for 25% step load  
change  
Transient Response  
o
Temperature Coefficient  
Short Circuit Protection  
0.02 % per C  
Current Limit,  
Continuous  
1
= % Output voltage measured from min. input line to maximum at 100% Load.  
= Output voltage measured from 25% Load to 100% Load, at Nominal Line.  
2
>> 1