Figure R25 - EIA Referenced Reel Dimensions for Radial-leaded Devices  
Reel  
Upper side  
Tape  
n
Direction  
of  
a
unreeling  
Lower side  
c
w
1
2
Cross section  
w
Optional shape: Circular or polygonal  
Part Numbering System for Radial-leaded Devices  
RUEF  
250  
U
2
Blank = Packaged in bags  
-1 = 25.4mm (1.0 inch) minimum lead length  
-2 = Tape and reel  
-AP = Ammo pack  
-X.X = Special lead cut length (inch)  
Modifier  
K = Standard kinked lead  
B = Special kinked lead  
S = Straight lead  
U = Uncoated device  
Hold current indicator  
Product series - An "F" at the end of product series  
indicates Pb-free version of product.  
WARNING: Application Limitations for the LVR Product Line  
1) Users should independently evaluate the suitability of and test each product selected for their own application.  
2) This product should not be used in an application where the maximum interrupt voltage or maximum interrupt current can  
be exceeded in a fault condition. Operation beyond the maximum ratings or improper use may result in device damage and  
possible electrical arcing and flame.  
3) A PTC device is not a fuse - it is a nonlinear thermistor that limits current. Because under a fault condition all PTC devices  
go into a high resistance state but not open circuit, hazardous voltage may be present at PTC locations.  
4) The devices are intended for protection against occasional overcurrent or overtemperature fault conditions and should not  
be used when repeated fault conditions or prolonged trip events are anticipated.  
5) In most applications, power must be removed and the fault condition cleared in order to reset a PTC device. However, under  
certain unusual conditions, a PTC device may automatically reset. Accordingly, PTC devices should not be used in an  
application where an automatic reset could create a safety hazard, such as garbage disposals and blenders.  
6) It is the responsibility of the user to determine the need for back up or fail safe protection to prevent damage that may occur  
in the event of abnormal function or failure of the PTC device.  
7) Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of a PTC device.  
8) Devices are not recommended for reflow soldering.  
9) Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic,  
thermal, or mechanical procedures for electronic components.  
10) PTC devices are not recommended to be installed in applications where the device is constrained such that its PTC properties  
are inhibited, for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device  
expansion.  
11) Contamination of the PTC material with certain silicone-based oils or some aggressive solvents can adversely impact the  
performance of the devices.  
13  