欢迎访问ic37.com |
会员登录 免费注册
发布采购

RTD34024 参数 Datasheet PDF下载

RTD34024图片预览
型号: RTD34024
PDF下载: 下载PDF文件 查看货源
内容描述: 通用继电器PCB继电器 [General Purpose Relays PCB Relays]
分类和应用: 继电器PC
文件页数/大小: 5 页 / 729 K
品牌: MACOM [ Tyco Electronics ]
 浏览型号RTD34024的Datasheet PDF文件第2页浏览型号RTD34024的Datasheet PDF文件第3页浏览型号RTD34024的Datasheet PDF文件第4页浏览型号RTD34024的Datasheet PDF文件第5页  
General Purpose Relays
PCB Relays
Power PCB Relay RT1
n
n
n
n
n
n
SCHRACK
1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact
DC or AC coil
5kV/10mm coil-contact, reinforced insulation
Ambient temperature 85°C (DC coil)
WG version: product in accordance to IEC 60335-1
Reflow version: for THR (Through-Hole Reflow) soldering process
Typical applications
Boiler control, timers, garage door control, POS automation, interface
modules
F0144-C
Zb
Contact Data
(continued)
Mechanical endurance
DC coil
AC coil
AC coil, reflow version
>30x10
6
operations
>10x10
6
operations
>5x10
6
operations
Approvals
VDE REG.-Nr. 6106, cULus E214025, cCSAus 14385; CQC
Technical data of approved types on request
Contact arrangement
1 form C (CO) or 1 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
12A
16A
Limiting continuous current
12A
16A, UL: 20A
Limiting making current
max. 4s, duty factor 10%
25A
30A
Breaking capacity max.
3000VA
4000VA
Contact material
AgNi 90/10, AgNi 90/10 gold plated
Frequency of operation, with/without load
DC coil
360/72000h
-1
AC coil
360/36000h
-1
Operate/release time max., DC coil
8/6ms
Bounce time max., DC coil, form A/form B
4/6ms
Electrical endurance
see electrical endurance graph
1)
Contact ratings
Type
Contact
IEC 61810
RT314 DC-coil A (NO)
RT314 DC-coil C (CO)
RT314 DC-coil A (NO)
RT114 DC-coil A (NO)
RT114 AC-coil A (NO)
UL 508
RT314
A/B (NO/NC)
RT334
A (NO)
RT314
A (NO)
RT314
A (NO)
EN60947-5-1
RT314 DC-coil A/B (NO/NC)
EN60730-1
RT314 DC-coil A (NO)
Load
16A, 250VAC, cosφ=1, 85°C
16A, 250VAC, cosφ=1, 85°C
10A, 400VAC, cosφ=1, 85°C
12A, 250VAC, cosφ=1, 85°C
12A, 250VAC, cosφ=1, 70°C
Cycles
30x10
3
10x10
3
150x10
3
50x10
3
100x10
3
Contact Data
12A
16A
Coil Data
Coil voltage range, DC coil/ AC coil
Operative range, IEC 61810
Coil insulation system according UL
Coil versions, DC coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
005
5
3.5
006
6
4.2
009
9
6.3
012
12
8.4
024
24
16.8
048
48
33.6
060
60
42.0
110
110
77.0
5 to 110VDC / 24 to 230VAC
2
class F
Release
voltage
VDC
0.5
0.6
0.9
1.2
2.4
4.8
6.0
11.0
Coil
resistance
Ω±10%
2)
62
90
200
360
1440
5520
8570
2)
28800
2)
Rated coil
power
mW
403
400
400
400
400
417
420
420
2) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
20A, 250VAC, general purpose, 85°C 6x10
3
16A, 250VAC, gen. purpose, 85°C
50x10
3
1hp, 240VAC, 40°C
1x10
3
FLA/LRA, 4.5/13.1A, 480VAC, 70°C 100x10
3
2A, 24VDC, DC13
12(2)A, 250VAC, 85°C
6.050
100x10
3
Coil versions, AC coil 50/60 Hz
Coil
Rated
Operate
code
voltage
voltage
VAC
VAC
524
24
18.0
615
115
86.3
620
120
90.0
700
200
150.0
730
230
172.5
Release
voltage
VAC
3.6
17.3
18.0
30.0
34.5
Coil
resistance
Ω±15%
3)
350
3)
8100
8800
24350
32500
Rated coil
power
VA
0.76
0.76
0.75
0.76
0.74
1) For reflow solderable versions: actual contact performance may be influenced by the
reflow soldering process.
3) Coil resistance ±10%.
All figures are given for coil without pre-energization, at ambient temperature +23°C, 50 Hz.
Other coil voltages on request.
07-2012, Rev. 0712
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1