SPECIFICATION RT-1116 Issue 5
Page 7
TABLE 3
REQUIREMENTS
(continued)
PROPERTY
CHEMICAL
Corrosive Effect
16 hours at 135°C
(275°F)
Flammability
Average time of burning
Fungus Resistance
Fluid Resistance
24 hours at 23°C
(73°F)
JP-4 Fuel (MIL-DTL-5624)
Hydraulic Fluid (MIL-PRF-5606)
Anti-Icing Fluid (SAE-AMS1424)
Lubricating Oil (MIL-PRF-23699F )
Cleaning Compound (A-A-59133)
Water
Followed by tests for:
Tensile Strength
Ultimate Elongation
Weight Increase
Fluid Resistance
24 hours at 50°C
(122°F)
DF-2 (A-A-52557)
JP-4 Fuel (MIL-DTL-5624)
Followed by tests for:
Tensile Strength
Ultimate Elongation
Weight Increase
Fluid Resistance
24 hours at 71°C
(160°F)
Hydraulic Fluid (MIL-PRF-6083)
Hydraulic Fluid (MIL-PRF-46170D )
Followed by tests for:
Tensile Strength
Ultimate Elongation
Weight Increase
UNIT
REQUIREMENT
TEST METHOD
---
Noncorrosive
Seconds
---
---
15 maximum
Rating of 1 or less
---
Section 4.3.7
ASTM D 2671
ASTM D 2671
Procedure A
ASTM G 21
Section 4.3.8
psi
(MPa)
Percent
Percent
---
1500 minimum
(10.3)
300 minimum
15 maximum
---
Section 4.3.2
Section 4.3.2
Section 4.3.8
psi
(MPa)
Percent
Percent
---
1500 minimum
(10.3)
300 minimum
20 maximum
---
Section 4.3.2
Section 4.3.2
Section 4.3.8
Section 4.3.8
psi
(MPa)
Percent
Percent
1500 minimum
(10.3)
300 minimum
15 maximum
Section 4.3.2
Section 4.3.2
Section 4.3.8
If this document is printed it becomes uncontrolled. Check for the latest revision.
2005-2012
Tyco Electronics Corporation. All rights reserved