General Purpose Relays
Industrial Relays
Potter & Brumfield
R10 Series Panel Plug-in Relay (Continued)
Coil versions, DC coil (continued)
Operative Range
R10 Relays (DC Only) Typical Ranges of Operations @ 25°C
Coil
code
Maximum
coil current
mADC
Operate
current
mADC
Coil
resistance
Ω 10ꢀ
Pick-up
coil power
mW
(Curves for reference only. If specific
J - sensitive DC current adjustment – R10S types only
values are required, testing is required.)
2 pole
30
25
12
10
1)
J500
J1.0K
J2.5K
J5.0K
J10.0K
J16.0K
J30.0K
4 pole
J500
J1.0K
J2.5K
J5.0K
J10.0K
J16.0K
J30.0K
–
–
–
–
–
–
–
6.3
4.5
2.9
2
1.4
1.2
0.8
500
1000
2500
5000
10000
16000
30000
20
20
25
20
20
25
20
Typical Operate
and Release Time
2)
(all contact configurations)
8
6
4
2
20
15
10
5
3)
Release Time
(no suppression)
–
–
–
–
–
–
–
9
500
1000
2500
5000
10000
16000
30000
45
45
45
45
40
35
45
6.5
4.1
2.9
2
1.4
1.2
2)
3)
Operate Time
1.0
1.33 1.5
2.0
2.5
3.0
Multiple of Max. Pull-in Voltage or Current
1) Suggested for 5VDC operation
2) Suggested for 12VDC operation
3) Suggested for 24VDC operation
R10 Ultra-Sensitive “SS” and “JJ” Typical Ranges of Operation @ 25°C
JJ - ultrasensitive DC current adjustment
1 pole
(Curves for reference only. If specific
values are required, testing is required.)
10
8
50
JJ1.0K
JJ2.5K
JJ5.0K
JJ10.0K
JJ15.0K
JJ30.0K
2 pole
JJ1.0K
JJ2.5K
JJ5.0K
JJ10.0K
JJ15.0K
JJ30.0K
4 pole
45
28
20
14
11.5
8.3
4.5
2.9
2.1
1.5
1.2
0.85
1000
2500
5000
10000
15000
30000
20
25
25
25
25
25
Typical Operate
and Release Time
(all contact configurations)
40
30
6
Release Time
(no suppression)
45
28
20
14
11.5
8.3
6.5
4.1
2.9
2
1.7
1.2
1000
2500
5000
10000
15000
30000
45
45
45
40
45
45
20
10
4
2
Operate Time
3.0
4.0
1.0
1.5 2.0
JJ1.0K
JJ2.5K
JJ5.0K
JJ10.0K
JJ15.0K
JJ30.0K
45
28
20
14
11.5
8.3
9
1000
2500
5000
10000
15000
30000
85
85
85
90
85
90
Multiple of Max. Pull-in Voltage or Current
5.8
4.1
3
2.4
1.7
Typical Coil Inductance
500
All figures are given for coil without preenergization, at ambient temperature +23°C.
100
50
Coil versions, AC coil (dual coil diode rectified construction)
Coil
Rated
voltage
VAC
Operate
voltage
VAC
Coil
resistance
Ω 20ꢀ
code
10
Armature (open)
Armature (closed)
Standard AC
2 and 4 pole
6V
12V
24V
48V
115V
6 and 8 pole
6V
12V
6
5
9
18
36
86
25
120
500
2000
9000
1.0
0.5
12
24
48
115
0.1
10
50 100
500 1K
Coil Resistance (Ohms)
5K 10K
100K
6
5
9
18
36
86
15
90
350
1400
7500
12
24
48
115
24V
48V
115V
All figures are given for coil without preenergization, at ambient temperature +23°C.
3
08-2011, Rev. 0811
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company