RAYCHEM Tubing Products
Model 105 (Continued)
Electrical
Specifications and
Dimensions
Power requirements
Heating elements
Drive system
210-240 VAC, 20A, 1∅, 50/60 Hz
(2) 1500 watt infrared stamped foil with black quartz face, one top & bottom
DC gear motor with closed loop motor controller, 3-digit thumbwheel
4 – 100 CFM fans, 2 - for upper heater housing, 2 – for product cooling
Set Point (Heater Surface) - Ambient to 700°C, Throughput = 50° to 200°C
Air flow (cooling)
Operating temperature
Mechanical
Conveyor belt system
Belt Speed
Wire mesh 70% open, with optional Teflon coating
6.1 cm [0.2 ft] to 152 cm [5.0 ft] per minute
Dimensions cm [in]
Processor dimensions
Processor weight
99 cm [39 in] L x 68.5 cm [27 in] W x 41.7 cm [16.5 in] H
68 Kg [150 lb]
Control box dimensions
Control box weight
Shipping dimensions
Shipping weight
51.5 cm [20.25 in] L x 21.0 cm [8.25 in] W x 17.8 cm [7.0 in] H
7.7 Kg [17 lb]
134.6 cm [53 in] L x 116.8 cm [46 in] W x 63.5 cm [25 in] H
146 Kg [320 lbs]
Tubing sizes
Tubing diameter (max)
Tubing length (max)
Up to 76.2 mm [3.0 in]
356 mm [14 in] perpendicular to belt travel, unlimited length parallel to belt travel
Version
Description
Part No.
Model 105 Tunnel Oven
CLTEQ-M105-TUNNEL-OVEN
955018-000
2-16
9-1773447-9
Dimensions are in inches and
Dimensions are shown for
USA: 1-800-522-6752
Germany: 49-6251-133-1999
China: 86-400-820-6015
Japan: 81-44-844-8013
UK: 44-800-267-666
CIS WR 08/2011
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
reference purposes only.
Specifications subject
to change.
Canada: 1-905-475-6222
Mexico: 52-55-1106-0800
te.com
L. & S. America: 54-11-4733-2200