Table SFV1 Clear Time Characteristics for 2410 Very Fast-Acting Fuses
% of rated current
100%
Clear time at 25°C
4 hours (min.)
200% (0.5A-10.0A)
200% (12.0A-20.0A)
0.01 second (min.)
0.01 second (min.)
5 seconds (max.)
20 seconds (max.)
Typical Electrical Characteristics, Dimensions and Recommended Pad Layout for
2410 Very Fast-Acting Fuses
Table SFV2
2410 (6125 mm) Very Fast-Acting Fuse
Shape and Dimensions
mm (Inch)
Recommended Pad Layout
mm (Inch)
A
B
C
D
6.86
(0.270)
D
Min
Max
Min
Min
Max
Min
Max
A
2.95
(0.116)
C
mm
in
5.95
6.25
1.73
2.34
2.64
(0.234) (0.246) (0
.077) (
0.093
) (0
.038) (0.068) (0.092) (0.104)
3.15
(0.124)
B
1.96
(0.077)
Ty
pical El
ect
ric
al Char
acte
ristics
Max. Interrupt Ratings
Rated
Current
(A)
Nominal
I2t
Voltage
Marking
Current
(A)
Part Number
(A2sec)
(VAC
)
(VDC
)
2410SFV0.50FM/125-2
2410SFV0.63FM/125-2
2410SFV0.75FM/125-2
2410SFV1.00FM/125-2
2410SFV1.25FM/125-2
2410SFV1.50FM/125-2
2410SFV2.00FM/125-2
2410SFV2.50FM/125-2
2410SFV3.00FM/125-2
2410SFV3.15FM/125-2
2410SFV3.50FM/125-2
2410SFV4.00FM/125-2
2410SFV5.00FM/125-2
2410SFV6.30FM/125-2
2410SFV7.00FM/125-2
2410SFV8.00FM/125-2
C
0.5
0.6
0.8
1.0
1.3
1.5
2.0
2.5
3.0
3.2
3.5
4.0
5.0
6.3
7.0
8.0
0.0700
0.0620
0.0420
0.0310
0.0249
0.0232
0.0220
0.0172
0.0143
0.0100
0.0094
0.0086
0.10
0.16
0.23
0.59
0.96
1.19
2.75
1.21
1.73
2.20
2.50
4.10
5.90
12.50
14.20
20.30
250
125
S
D
E
F
250
250
250
250
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
50A @ 250VAC
50A @ 125VDC
300A @ 32VDC
G
I
11
J
K
V
L
50A @ 125VAC
50A @ 125VDC
300A @ 32VDC
M
N
O
P
R
35A @ 125VAC
50A @ 125VDC
300A @ 32VDC
2410SFV10.0FM/125-2
Q
10.0
0.0066
29.20
125
125
50A @ 65VAC
50A @ 65VDC
300A @ 32VDC
2410SFV12.0FM/065-2
2410SFV15.0FM/065-2
X
Y
12.0
15.0
0.0053
0.0038
49.20
65
65
65
65
102.50
50A @ 65VAC
50A @ 65VDC
300A @ 32VDC
2410SFV20.0FM/065-2
Z
20.0
0.0034
126.20
65
65
* Measured at Յ10% of rated current and 25°C ambient temperature.
94
RoHS Compliant, ELV Compliant
HF Halogen Free