108-98001 Rev. M
AXICOM Signal Relays
IM Relay
Contact Data
IM-A
IM-B
IM-C
IM-D
IM-E
Number of contacts and type
1 Pole break
1 Pole make
1 Pole
2 Pole break
2 Pole make
changeover
Contact assembly
Contact material
Bifurcated contacts
Palladium-ruthenium, gold-covered
Limiting continuous current
at max. ambient temperature
Maximum switching current
2 A
2 A
2 A
4 A
2 A
2 A
2 A
2 A
3 A
2 A
Maximum swichting voltage
220 Vdc
250 Vac
Maximum switching capacity
Thermoelectric potential
Minimum switching voltage
Initial contact resistance /
60 W, 62.5 VA
< 10 µV
100 µV
< 100 mΩ
< 100 mΩ
NO < 100 mΩ
< 50 mΩ
< 50 mΩ
measuring condition: 10 mA / 20 mV
Electrical
CC0 Contact category 0
endurance
(≤ 30 mV / ≥ 10 mA)
cable load open end
min. 2.5 x 106 operations
min. 2.0 x 106 operations
Resistive load
VA
at 125 Vdc / 0.24 A - 30 W
at 220 Vdc / 0.27 A - 60 W
at 250 Vac / 0.25 A - 62.5
min. 5 x 105 operations
min. 1 x 105 operations
min. 1 x 105 operations
min. 5 x 105 operations
min. 1 x 105 operations
at 30 Vdc / 1 A - 30 W
at 30 Vdc / 2 A - 60 W
Mechanical endurance
typ. 108 operations
220 Vdc / 0.24 A - 60 W
125 Vdc / 0.24 A - 30 W
UL contact ratings
250 Vac / 0.25 A - 62.5 VA
125 Vac / 0.5 A - 62.5 VA
30 Vdc / 2 A - 60 W
Max. DC Load Breaking Capacity
resistive load
DC current [A]
All specifications subject to change. Consult Tyco Electronics for latest specifications.
21 of 28