Corcom Product Guide
Medium Performance Compact EMI Power Inlet Filter
Catalog: 1654001
Issue Date: 06.2011
ED Series
ED2
UL Recognized
CSA Certified
VDE Approved*
ED1 / ED1C
EC8 / ED8C
EC4 / ED4C
ED Series
• Two element circuit provides medium attenuation
• Available with an internal ground-circuit inductor
(C versions) to isolate equipment chassis from
power line ground at radio frequencies
• Versions up to 15A*
• Similar to EEJ Series with alternative termination
options
• See the EC Series for better differential mode
performance
Specifications
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
.22 mA
@250 VAC 50 Hz:
.38 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max.):
Operating Frequency:
Rated Current:
2250 VDC
1450 VDC
250 VAC
50/60 Hz
1 to 15A*
Ordering Information
3 ED 1 C
Ground Circuit Inductor
Omit if none
Output Styles
1 – .250 [6.3] spade terminals
(back)
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
(85-Ta)/45
Available Part Numbers
1ED1
3ED1
6ED1
10ED1
15ED1
6ED1C
10ED1C
1ED2
3ED2
6ED2
1ED4
3ED4
6ED4
1ED8
3ED8
6ED8
15ED8
6ED4C
6ED8C
2 – .250 [6.3] spade terminals
(bottom)
4 – Wire leads
(bottom)
8 – Wire leads
(back)
ED Series
Current Rating
1, 3, 6, 10 or 15A
Ground Circuit Inductor Versions
Electrical Schematic
LINE
1
LOAD
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 10A, 250VAC
Note 1: C versions
Versions only
Note 1: C
only
144
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com