Absolute Maximum Ratings
Table 5.
LUXEON Rebel ES
Royal-Blue
1000
Parameter
Green/Cyan/
Blue/Royal-Blue
1000
Red/Deep-Red
Red-Orange/Amber
PC Amber
700
DC Forward Current (mA)
Peak Pulsed Forward
Current (mA)
700
700
1000
1200
700
Average Forward Current (mA)
1000
1000
700
700
ESD Sensitivity
< 8000V Human Body Model (HBM) Class 3A JESD22-A114-B
LED JunctionTemperature [1]
Operating CaseTemperature
at 350 mA
150°C
150°C
135°C
130°C
-40°C - 135°C
-40°C - 135°C
-40°C - 120°C
-40°C - 110°C
StorageTemperature
SolderingTemperature
Allowable Reflow Cycles
-40°C - 135°C
JEDEC 020c 260°C
3
-40°C - 135°C
JEDEC 020c 260°C
3
-40°C - 135°C
JEDEC 020c 260°C
3
-40°C - 135°C
JEDEC 020c 260°C
3
Autoclave Conditions 121°C at 2 ATM 100% Relative Humidity for 96 Hours Maximum
LUXEON Rebel Color Portfolio LEDs are not designed to be driven in reverse bias.
ReverseVoltage (Vr)
Notes forTable 5:
1. Proper current derating must be observed to maintain junction temperature below the maximum.
2. The maximum rating for LUXEON Rebel ES royal-blue is 1200 mA with peak pulsed forward current not to exceed 60 seconds.
JEDEC Moisture Sensitivity
Table 6.
Soak Requirements
Level
Floor Life
Standard
Time
(hours)
168
Conditions
Time
unlimited
Conditions
[ 30°C /
85% RH
1
85°C / 85%
RH
+ 5 / -0
LUXEON Rebel Color Porfolio Datasheet DS68 20110819
8