Absolute Maximum Ratings
Table 5.
White/Green/
Cyan/Blue/
Royal Blue
Red/
RedꢀOrange/
Amber
Warm
White
Parameter
[1]
DC Forward Current (mA)
350
500
350
350
385
550
350
Peak Pulsed Forward Current (mA)
Average Forward Current (mA)
500
350
[2]
ESD Sensitivity
16,000V HBM
120
LED Junction Temperature (°C)
Storage Temperature (°C)
135
120
ꢀ40 to +120
ꢀ40 to +120
ꢀ40 to +120
[3]
Soldering Temperature (°C)
260 for 5
260 for 5
260 for 5
seconds max
seconds max
seconds max
Notes for Table 5:
1. Proper current derating must be observed to maintain junction temperature below the maximum. For more information,
consult the LUXEON Design Guide, available upon request.
2. LEDs are not designed to be driven in reverse bias. Please consult Philips Lumileds' Application Brief AB11 for further
information.
3. Measured at leads, during lead soldering and slug attach, body temperature must not exceed 120°C. LUXEON emitters
cannot be soldered by general IR or Vaporꢀphase reflow, nor by wave soldering. Lead soldering is limited to selective
heating of the leads, such as by hotꢀbar reflow, fiber focussed IR, or hand soldering. The package back plane (slug) may
not be attached by soldering, but rather with a thermally conductive adhesive. Electrical insulation between the slug and
the board is required. Please consult Philips Lumileds' Application Brief AB10 on LUXEON Emitter Assembly Information
for further details on assembly methods.
LUXEON Emitter DS25 (5/07)
7