Absolute Maximum Ratings
Table 4a. Absolute maximum ratings for LUXEON SunPlus 20 Line.
PaꢅamEtEꢅ
Faꢅ ꢅEd
dEEP ꢅEd
ꢅoyal BluE
lImE
ꢆool WHItE
DC Forward Current[1, 2]
Peak Pulsed Forward Current[1, 3]
LED Junction Temperature[1] (DC & Pulse)
ESD Sensitivity (ANSI/ESDA/JEDEC JS-001-2012)
Operating Case Temperature[1]
LED Storage Temperature
700mA
1050mA
1300mA
120°C
700mA
1050mA
1300mA
120°C
1050mA
1300mA
135°C
1225mA
1550mA
135°C
1225mA
1550mA
135°C
875mA
135°C
875mA
135°C
Class 3B
-40 to 125°C
-40°C to 135°C
-40 to 125°C
-40 to 125°C
-40 to 110°C
-40 to 125°C
Soldering Temperature
20°C to 260°C
3
Allowable Reflow Cycles
Reverse Voltage (Vreverse
)
LUXEON LEDs are not designed to be driven in reverse bias
Table 4b. Absolute maximum ratings for LUXEON SunPlus 35 Line.
PaꢅamEtEꢅ
PuꢅPlE
Faꢅ ꢅEd
dEEP ꢅEd
ꢅoyal BluE
lImE
DC Forward Current[1, 2]
Peak Pulsed Forward Current[1, 3]
LED Junction Temperature[1] (DC & Pulse)
ESD Sensitivity (ANSI/ESDA/JEDEC JS-001-2012)
Operating Case Temperature[1]
LED Storage Temperature
300mA
350mA
125°C
180mA
225mA
115°C
180mA
225mA
115°C
200mA
480mA
125°C
200mA
240mA
125°C
Class 2
-40°C to 105°C
-40°C to 105°C
-40°C to 105°C
-40°C to 105°C
-40°C to 105°C
-40°C to 105°C
-40°C to 95°C -40°C to 105°C
-40°C to 95°C -40°C to 105°C
Soldering Temperature
20°C to 260°C
Allowable Reflow Cycles
3
Reverse Voltage (Vreverse
)
LUXEON LEDs are not designed to be driven in reverse bias
Notes for Tables 4a and 4b:
1. Proper current derating must be observed to maintain the junction temperature below the maximum allowable junction temperature.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple,” with frequencies ≥100Hz and amplitude of ≤15% of the maximum
allowable DC forward current are acceptable, assuming the average current throughout each cycle does not exceed the maximum allowable DC forward current at the corresponding
maximum junction temperature.
3. Pulsed operation with a peak drive current equal to the stated peak pulsed forward current is acceptable if the pulse-on time is ≤5ms per cycle and the duty cycle is ≤50%.
4. Transient reverse voltages and surge currents due to electrical switching or supply interruptions are acceptable if these events do not last for more than 10ms, the amplitude of the reverse
voltage does not exceed 5V and the reverse current is less than 220uA.
5. Max 5V reverse for up to 10s is an acceptable beginning of life, one time test condition.
DS171 LUXEON SunPlus Series for Horticulture Product Datasheet 20171212 ©2017 Lumileds Holding B.V. All rights reserved.
5