Electrical and Thermal Characteristics
Table 3ꢀ Electrical and thermal characteristics for LUXEON CZ Color Line at 350mA, Tj=85ºCꢀ
FoꢃWaꢃd VoltaGE [1] (Vf)
tyPICal tEmPEꢃatuꢃE
CoEFFICIEnt oF FoꢃWaꢃd
VoltaGE [2] (ꢄV/°C)
tyPICal tHEꢃmal
ꢃEsIstanCE—JunCtIon
to soldEꢃ Pad (°C/W)
Coloꢃ
Paꢃt numBEꢃ
mInImum tyPICal maXImum
Far Red
Deep Red
Red
L1CU-FRD1000000000
L1CU-DRD1000000000
L1CU-RED1000000000
L1CU-RNG1000000000
L1CU-AMB1000000000
L1CU-PCA1000000000
L1CU-MNT1000000000
L1CU-LME1000000000
L1CU-GRN1000000000
L1CU-CYN1000000000
L1CU-BLU1000000000
L1CU-RYL0000000000
L1CU-VLT1000000000
L1CU-xxx0000000000
1.50
1.50
1.75
1.75
1.75
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
1.73
2.00
2.00
2.05
2.05
2.75
2.75
2.75
3.05
3.05
2.83
2.75
2.83
2.75
2.30
2.30
2.50
2.50
2.50
3.50
3.50
3.50
3.50
3.50
3.50
3.50
3.50
3.50
-1.7
-1.7
-1.6
-1.6
-2.0
-1.7
-2.7
-2.7
-2.4
-2.4
-2.6
-1.7
-1.7
-1.7
3.5
3.5
3.5
3.5
3.5
3.5
3.2
3.2
4.0
4.0
4.0
3.2
3.2
3.2
Red-Orange
Amber
PC Amber
Mint
Lime
Green
Cyan
Blue
Royal Blue
Violet
White
Notes for Table 3:
1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements.
2. Measured between 25°C and 85°C.
Absolute Maximum Ratings
Table 4ꢀ Absolute maximum ratings for LUXEON CZ Color Lineꢀ
Faꢃ ꢃEd,
mInt, lImE,
GꢃEEn
BluE
PaꢃamEtEꢃ
dEEP ꢃEd
ꢃEd, ꢃEd-oꢃanGE,
VIolEt
and Cyan and ꢃoyal BluE
amBEꢃ and PC amBEꢃ
and WHItE
DC Forward Current[1,2]
Peak Pulsed Forward Current[1,3]
LED Junction Temperature[1] (DC & Pulse)
700mA
1050mA
1300mA
80°C
1050mA
1300mA
120°C
1050mA
1300mA
135°C
1050mA
1300mA
135°C
1225mA
1500mA
135°C
875mA
100°C
ESD Sensitivity
(ANSI/ESDA/JEDEC JS-001-2012)
Class 3B
LED Storage Temperature
Soldering Temperature
Allowable Reflow Cycles
-40°C to 135°C
JEDEC 020c 260°C
3
Reverse Voltage (Vreverse
)
LUXEON C LEDs are not designed to be driven in reverse bias
Notes for Table 4:
1. Proper current derating must be observed to maintain the junction temperature below the maximum allowable junction temperature.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple,” are acceptable if the following conditions are met:
– The frequency of the ripple current is 100Hz or higher
– The average current for each cycle does not exceed the maximum allowable DC forward current
– The maximum amplitude of the ripple does not exceed the maximum peak pulsed forward current
3. At 10% duty cycle with pulse width of 10ms.