Forward Voltage Bins
Table 11. Forward voltage bin definitions for LUXEON CZ Color Line.
FoꢃWaꢃd VoltaGE [1] (Vf)
BIn
mInImum
maXImum
1.70
Z
A
B
C
D
E
1.50
1.70
1.90
2.10
2.30
2.50
2.70
2.90
3.10
1.90
2.10
2.30
2.50
2.70
F
2.90
G
H
3.10
3.30
Notes for Table 11:
1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements.
Mechanical Dimensions
Figure 11ꢀ Mechanical dimensions for LUXEON CZ Color Lineꢀ
Notes for Figure 11:
1. Drawings are not to scale.
2. All dimensions are in millimeters.
DS198 LUXEON CZ Color Line Product Datasheet 20180606 ©2018 Lumileds Holding B.V. All rights reserved.
25