Electrical and Thermal Characteristics
Table 3 . Electrical and thermal characteristics for LUXEON CZ Color Line at 350mA, T
j
=85ºC .
Color
Far Red
Deep Red
Red
Red-Orange
Amber
PC Amber
Mint
Lime
Green
Cyan
Blue
Royal Blue
Violet
White
Part numBEr
L1CU-FRD1000000000
L1CU-DRD1000000000
L1CU-RED1000000000
L1CU-RNG1000000000
L1CU-AMB1000000000
L1CU-PCA1000000000
L1CU-MNT1000000000
L1CU-LME1000000000
L1CU-GRN1000000000
L1CU-CYN1000000000
L1CU-BLU1000000000
L1CU-RYL0000000000
L1CU-VLT1000000000
L1CU-xxx0000000000
ForWard VoltaGE
[1]
(V
f
)
mInImum
1.50
1.50
1.75
1.75
1.75
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
tyPICal
1.73
2.00
2.00
2.05
2.05
2.75
2.75
2.75
3.05
3.05
2.83
2.75
2.83
2.75
maXImum
2.30
2.30
2.50
2.50
2.50
3.50
3.50
3.50
3.50
3.50
3.50
3.50
3.50
3.50
tyPICal tEmPEraturE
CoEFFICIEnt oF ForWard
VoltaGE
[2]
(mV/°C)
-1.7
-1.7
-1.6
-1.6
-2.0
-1.7
-2.7
-2.7
-2.4
-2.4
-2.6
-1.7
-1.7
-1.7
tyPICal tHErmal
rEsIstanCE—JunCtIon
to soldEr Pad (°C/W)
3.5
3.5
3.5
3.5
3.5
3.5
3.2
3.2
4.0
4.0
4.0
3.2
3.2
3.2
Notes for Table 3:
1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements.
2. Measured between 25°C and 85°C.
Absolute Maximum Ratings
Table 4 . Absolute maximum ratings for LUXEON CZ Color Line .
ParamEtEr
DC Forward Current
[1, 2]
Peak Pulsed Forward Current
[1, 3]
LED Junction Temperature
[1]
(DC & Pulse)
ESD Sensitivity
(ANSI/ESDA/JEDEC JS-001-2012)
LED Storage Temperature
Soldering Temperature
Allowable Reflow Cycles
Reverse Voltage (V
reverse
)
dEEP rEd
700mA
875mA
135°C
Far rEd,
rEd, rEd-oranGE,
amBEr and PC amBEr
1050mA
1300mA
120°C
GrEEn
and Cyan
1050mA
1300mA
135°C
Class 3B
-40°C to 135°C
JEDEC 020c 260°C
3
LUXEON C LEDs are not designed to be driven in reverse bias
BluE
and royal BluE
1050mA
1300mA
135°C
mInt, lImE,
VIolEt
and WHItE
1225mA
1500mA
135°C
Notes for Table 4:
1. Proper current derating must be observed to maintain the junction temperature below the maximum allowable junction temperature.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple,” are acceptable if the following conditions are met:
– The frequency of the ripple current is 100Hz or higher
– The average current for each cycle does not exceed the maximum allowable DC forward current
– The maximum amplitude of the ripple does not exceed the maximum peak pulsed forward current
3. At 10% duty cycle with pulse width of 10ms.
DS198 LUXEON CZ Color Line Product Datasheet 20190120 ©2019 Lumileds Holding B.V. All rights reserved.
5