Forward Voltage Bins
Table 7. Forward voltage bin definitions for LUXEON 5050, Tj=25°Cꢀ
ForWard VoltaGE [1] (Vf)
Part numBEr
BIn
mInImum
23.5
24.2
25.0
25.8
5.8
maXImum
24.2
25.0
25.8
26.5
6.0
A1
A2
B1
B2
A1
A2
B1
B2
L150-xxxx502400000
6.0
6.2
L150-xxxx500600000
6.2
6.4
6.4
6.6
Notes for Table 7:
1. Lumileds maintains a tolerance of ±1% on forward voltage measurements.
Mechanical Dimensions
Figure 8ꢀ Mechanical dimensions for LUXEON 5050ꢀ
Notes for Figure 8:
1. Drawings are not to scale.
2. All dimensions are in millimeters.
DS174 LUXEON 5050 Product Datasheet 20170604 ©2017 Lumileds Holding B.V. All rights reserved.