Product Selection
Product Selection Guide for LUXEON 3030 2D
Junction Temperature = 25°C
Table 1.
Luminous Flux (lm)
[1]
@ 120 mA
Minimum
2700K
3000K
3500K
4000K
5000K
5700K
6500K
L130-2780003000W21
L130-3080003000W21
L130-3580003000W21
L130-4080003000W21
L130-5080003000W21
L130-5780003000W21
L130-6580003000W21
80
80
80
80
80
80
80
77
85
82
84
86
87
87
Typical
84
90
93
95
96
97
97
Luminous Flux (lm)
[2]
@ 100 mA
Typical
71
75
79
81
81
82
82
12
R
th_J_c
(°C/W)
[3]
Typical
Nominal
CCT
Part Number
Minimum
CRI
[1]
Notes for Table 1:
1. Philips Lumileds maintains a tolerance of ± 7.5% on luminous flux, ± 2 on CRI.
2. Interpolated value.
3. Thermal resistance is measured junction to case.
Electrical Characteristics
Junction Temperature = 25°C, Test Current @ 120 mA
Table 2.
Forward Voltage V
f [1] [3]
(V)
Part Number
Minimum
L130-2780003000W21
L130-3080003000W21
L130-3580003000W21
L130-4080003000W21
L130-5080003000W21
L130-5780003000W21
L130-6580003000W21
Notes for Table 2:
1. Philips Lumileds maintains a tolerance of ± 0.1V on forward voltage measurements.
2. Measured between T
j
= 25°C and T
j
= 85°C.
3. Forward voltage test tolerance: ± 0.1 volts.
Typical
Maximum
Typical Temperature Coefficient of Forward
Voltage Between 25°C and 85°C
[2]
DV
F
/
DT
J
5.8
6.1
6.6
-2.0 to -4.0
LUXEON 3030 2D Datasheet DS207 20140414 ©2014 Philips Lumileds Lighting Company.
3