Electrical and Thermal Characteristics
Table 3ꢀ Electrical and thermal characteristics for LUXEON 2835 Line at test current, Tj=25°Cꢀ
ForWard VoltagE [1] (Vf)
tyPIcal tEmPEraturE
coEFFIcIEnt oF ForWard
VoltagE [2] (ꢂV/°c)
tyPIcal thErmal
rEsIstancE—JunctIon
to soldEr Pad (°c/W)
Part numBEr
mInImum
tyPIcal
maXImum
L128-xxxxCA35000x1
L128-xxxxCB3500001
L128-xxxxEA3500001
L128-xxxxEB3500001
L128-xxxxEC3500001
2.9
5.8
2.7
5.8
8.7
3.0
6.1
3.0
6.1
9.1
3.2
6.6
3.3
6.6
9.9
-1.0 to -2.0
-2.0 to -4.0
-1.0 to -2.0
-2.0 to -4.0
-3.0 to -6.0
21
11
39
20
15
Notes for Table 3:
1. Lumileds maintains a tolerance of ±0.1V on forward voltage measurements.
2. Measured between 25°C and 85°C.
Absolute Maximum Ratings
Table 4ꢀ Absolute maximum ratings for LUXEON 2835 Lineꢀ
ParamEtEr
maXImum PErFormancE
150mA for L128-xxxxEC3500001
150mA for L128-xxxxEB3500001
150mA for L128-xxxxEA3500001
240mA for L128-xxxxCx3500001
DC Forward Current[1, 2]
200mA for L128-xxxxEx3500001
300mA for L128-xxxxCx35000x1
Peak Pulsed Forward Current[1, 3]
115°C for L128-xxxxEA3500001
125°C for L128-xxxxEB3500001
125°C for L128-xxxxEC3500001
125°C for L128-xxxxCx3500001
LED Junction Temperature[1] (DC & Pulse)
Class 3B for LUXEON 2835C 3V TVS with ESD protection
Class 2 for all other LUXEON 2835 parts
ESD Sensitivity (ANSI/ESDA/JEDEC JS-001-2012)
Operating Case Temperature[1]
LED Storage Temperature
Soldering Temperature
-40°C to 105°C
-40°C to 105°C
JEDEC 020c 260°C
Allowable Reflow Cycles
Reverse Voltage[4, 5] (Vreverse
3
5
)
Notes for Table 4:
1. Proper current derating must be observed to maintain the junction temperature below the maximum allowable junction temperature.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple,” are acceptable if the following conditions are met:
– The frequency of the ripple current is 100Hz or higher
– The average current for each cycle does not exceed the maximum allowable DC forward current
– The maximum amplitude of the ripple does not exceed the maximum peak pulsed forward current
3. At ≤50% duty cycle with pulse width of 5ms.
4. Transient reverse voltages and surge currents due to electrical switching or supply interruptions are acceptable if these events do not last for more than 10ms, the amplitude of the reverse
voltage does not exceed 5V and the reverse current is less than 220uA.
5. Max 5V reverse for up to 10s is an acceptable beginning of life, one time test condition.
DS216 LUXEON 2835 Line Product Datasheet 20180118 ©2018 Lumileds Holding B.V. All rights reserved.
5