Enclosure~less Wiring Solution for On-Machine Applications  
Active/Passive Application Diagram  
Legend  
1. Passive Distribution Boxes  
Many styles to choose from. 4-, 6-, or 8-ports, top or side entry, with on-board, homerun  
cable, or quick-disconnect connector.  
2. Cordsets  
Single- and Double-Ended Cordsets provide connection between field devices and the  
ports of a distribution box or may be used to hardwire a device to a control panel or  
distribution box.  
3. Receptacles  
Receptacles are connectors that mount in a fixed location (sensor or panel) and mate with  
a molded cable.  
4. Field Attachable Connectors  
Used to complete the assembly of a single-ended cordset. Field attachables are available in  
a variety of thread sizes and number of poles, straight and right-angle or to make cordset  
repairs in the field.  
5. DIN Valve Connectors  
Are mainly used with solenoid valves in hydraulic and pneumatic applications. In addition,  
these connectors are also used in electrical applications for pressure switches, filter  
switches, limit switches and special sensors.  
6. Splitters  
Devices that provide the means of bringing two different sensor/actuator signals into a  
single port of an ASB distribution box, thereby doubling the capacity of the box.  
7. Fieldbus I/O Blocks  
Have embedded communications protocol, e.g., DeviceNet, Profibus...) that allows them to  
actively communicate with the network interface at the PLC.  
8. Fieldbus I/O Modular Bus Systems  
Are systems with bus-neutral I/O modules and communications adapters that allow the  
designer to mix and match field bus and I/O hardware components as needed for the  
application.  
9. Bus Taps and Tees  
Connect drop lines to the main trunk line or combine power and signal using a  
hybrid cable.  
10. Drop and Trunk Cordsets  
When connecting multiple devices to a single communications trunk, the trunk is split with  
a T-connector. The cable that connects the device to the main trunk is referred to as a  
drop cable.  
11. Terminating Resistors  
Are placed at the end of a transmission line or daisy chain bus (such as in Devicenet),  
designed to match impedance and hence minimize signal reflections.  
8
1-717-217-2299  
www.lumberg-automationusa.com  
 复制成功!