欢迎访问ic37.com |
会员登录 免费注册
发布采购

QK016LH3 参数 Datasheet PDF下载

QK016LH3图片预览
型号: QK016LH3
PDF下载: 下载PDF文件 查看货源
内容描述: 交变双向可控硅( 6 A到40 A ) [Alternistor Triacs (6 A to 40 A)]
分类和应用: 可控硅
文件页数/大小: 10 页 / 183 K
品牌: LITTELFUSE [ LITTELFUSE ]
 浏览型号QK016LH3的Datasheet PDF文件第2页浏览型号QK016LH3的Datasheet PDF文件第3页浏览型号QK016LH3的Datasheet PDF文件第4页浏览型号QK016LH3的Datasheet PDF文件第5页浏览型号QK016LH3的Datasheet PDF文件第6页浏览型号QK016LH3的Datasheet PDF文件第8页浏览型号QK016LH3的Datasheet PDF文件第9页浏览型号QK016LH3的Datasheet PDF文件第10页  
Data Sheets  
Alternistor Triacs  
130  
120  
110  
100  
90  
130  
120  
110  
100  
90  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
CONDUCTION ANGLE: 360˚  
CASE TEMPERATURE: Measured as  
shown on Dimensional Drawing  
10A TO-220 (NON-ISOLATED)  
and D2 PAK  
12A TO-220 (ISOLATED)  
35 A TO-220 (Non-isolated)  
and TO-263  
6A TO-220  
(NON-ISOLATED)  
TO-263, TO-251  
and TO-252  
25 A and 30 A  
TO-220 (Isolated)  
40 A TO-218  
(Isolated)  
6A TO-220 (ISOLATED)  
80  
80  
25 A TO-220 (Non-isolated)  
TO-218 (Isolated)  
TO-263  
70  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
70  
CONDUCTION ANGLE: 360  
CASE TEMPERATURE: Measured as  
shown on Dimensional Drawing  
60  
˚
60  
50  
0
0
10  
20  
25  
30  
40  
] – Amps  
50  
0
2
4
6
8
10  
12  
14  
RMS On-State Current [l  
T(RMS)  
] - AMPS  
RMS On-state Current [l  
T(RMS)  
Figure E4.1 Maximum Allowable Case Temperature versus  
On-state Current (6 A to 12 A)  
Figure E4.4 Maximum Allowable Case Temperature versus  
On-state Current (25 A to 40 A)  
20  
18  
130  
12 A TO-220 (Non-isolated)  
and TO-263  
120  
T
= 25 ˚C  
C
16  
14  
12  
10  
8
110  
10 A TO-220 (Isolated)  
100  
90  
80  
70  
60  
0
6 A to 12 A Devices  
8 A TO-220 (Isolated)  
8 A TO-220 (Non-isolated),  
TO-263, TO-251, and TO-252  
6
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
CONDUCTION ANGLE: 360˚  
CASE TEMPERATURE: Measured as  
shown on Dimensional Drawing  
4
2
0
0.8  
0
0.6  
1.0  
1.2  
1.4  
1.6  
0
2
4
6
8
10  
12  
14  
Positive or Negative Instantaneous  
On-state Voltage (vT) – Volts  
RMS On-state Current [l  
] – Amps  
T(RMS)  
Figure E4.2 Maximum Allowable Case Temperature versus  
On-state Current (8 A to 12 A)  
Figure E4.5 On-state Current versus On-state Voltage (Typical)  
(6 A to 12 A)  
90  
80  
130  
120  
16A TO-220 (Non-isolated) and TO-263  
T
= 25˚C  
C
70  
60  
50  
40  
30  
20  
10  
0
110  
16A TO-220 (Isolated)  
40 A Devices  
100  
90  
25 A to 35 A Devices  
80  
CURRENT WAVEFORM: Sinusoidal  
70  
LOAD: Resistive or Inductive  
CONDUCTION ANGLE: 360  
˚
16 A Devices  
60  
CASE TEMPERATURE: Measured as  
shown on Dimensional Drawing  
0
0
5
10  
15  
0
0.6  
0.8  
1.0  
1.2  
1.4  
1.6  
1.8  
Positive or Negative Instantaneous On-state Voltage (v ) – Volts  
RMS On-state Current [IT(RMS)] – Amps  
T
Figure E4.3 Maximum Allowable Case Temperature versus  
On-state Current (16 A)  
Figure E4.6 On-state Current versus On-state Voltage (Typical)  
(16 A to 40 A)  
©2004 Littelfuse, Inc.  
Thyristor Product Catalog  
E4 - 7  
http://www.littelfuse.com  
+1 972-580-7777