LITE-ON TECHNOLOGY CORPORATION
P r o p e r t y o f L i t e - O n O n l y
Electrical / Optical Characteristics at TA=25°C
Parameter
Luminous Intensity
Viewing Angle
Symbol
IV
Min.
2500
32
Typ.
4200
36
Max.
Unit
mcd
deg
nm
nm
nm
V
Test Condition
IF = 20mA
Note 1,5
2θ1/2
Note 2 (Fig.5)
Measurement
@Peak (Fig.1)
Peak Emission Wavelength
Dominant Wavelength
Spectral Line Half-Width
Forward Voltage
λP
626
625
17
λd
620
1.9
630
Note 4
ꢀλ
VF
2.1
2.4
IF = 20mA
Reverse Current
IR
100
ꢁA
pF
VR = 5V
Capacitance
C
40
VF = 0 , f = 1MHz
NOTE: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
2. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. Iv classification code is marked on each packing bag.
4. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
5. The Iv guarantee should be added ±15% .
Part No. : LTL2V3EUJS-S-032A
BNS-OD-C131/A4
Page :
3
of
11