LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Electrical / Optical Characteristics at T
A
=25℃
Parameter
Luminous Intensity
Viewing Angle
Peak Emission Wavelength
Dominant Wavelength
Spectral Line Half-Width
Forward Voltage
Reverse Current
Capacitance
Symbol
I
V
2θ
1/2
λ
P
λ
d
∆λ
V
F
I
R
C
40
Min.
2500
Typ.
3200
30
590
589
15
2.2
2.6
100
Max.
Unit
mcd
deg
nm
nm
nm
V
µA
pF
I
F
= 20mA
V
R
= 5V
V
F
= 0 , f = 1MHz
Test Condition
I
F
= 20mA
Note 1
Note 2 (Fig.5)
Measurement
@Peak (Fig.1)
Note 4
NOTE: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
2.
θ
1/2
is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. Iv classification code is marked on each packing bag.
4. The dominant wavelength,
λd
is derived from the CIE chromaticity diagram and represents the
single wavelength which defines the color of the device.
Part No. : LTL2V3BYK
BNS-OD-C131/A4
Page :
3
of
10