Electrical / Optical Characteristics at TA=25℃
Parameter
Luminous Intensity
Viewing Angle
Symbol
IV
Min.
1150
Typ.
2500
30
Max.
Unit
mcd
deg
nm
nm
nm
V
Test Condition
IF = 20mA
Note 1
2θ1/2
Note 2 (Fig.5)
Measurement
@Peak (Fig.1)
Peak Emission Wavelength
Dominant Wavelength
Spectral Line Half-Width
Forward Voltage
λP
632
624
20
λd
Note 4
∆λ
VF
2.0
2.4
IF = 20mA
Reverse Current
IR
100
µA
pF
VR = 5V
Capacitance
C
40
VF = 0 , f = 1MHz
NOTE: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
2. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. Iv classification code is marked on each packing bag.
4. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
Part No. : LTL2V3UEK
BNS-OD-C131/A4
Page :
3
of
10