LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Electrical / Optical Characteristics at T
A
=25
°C
Parameter
Symbol
Min.
Typ.
Max.
Unit
Test Condition
I
F
= 20mA
Note 1,5
Note 2 (Fig.5)
Measurement
@Peak (Fig.1)
Note 4
Luminous Intensity
I
V
2500
4200
mcd
Viewing Angle
2θ
1/2
34
40
deg
Peak Emission Wavelength
λ
P
606
nm
Dominant Wavelength
λ
d
600
605
610
nm
Spectral Line Half-Width
∆λ
17
nm
Forward Voltage
V
F
1.8
2.1
2.5
V
I
F
= 20mA
Reverse Current
I
R
10
µA
V
R
= 5V
Capacitance
C
40
pF
V
F
= 0 , f = 1MHz
NOTE: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
2.
θ
1/2
is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. Iv classification code is marked on each packing bag.
4. The dominant wavelength,
λd
is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
5. The Iv guarantee should be added ±15% .
Part No. : LTL2V3FVJS
BNS-OD-C131/A4
Page :
3
of
10