LITE-ON TECHNOLOGY CORPORATION
P r o p e r t y o f L i t e - O n O n l y
℃
A
Electrical / Optical Characteristics at T =25
Parameter
Luminous Intensity
Viewing Angle
Symbol
IV
Min.
4200
Typ.
Max.
9300
Unit
mcd
deg
nm
nm
nm
V
Test Condition
IF = 20mA
Note 1 ,5
θ
2
1/2
30
639
630
17
Note 2 (Fig.5)
Measurement
@Peak (Fig.1)
λP
λd
Peak Emission Wavelength
Dominant Wavelength
Spectral Line Half-Width
Forward Voltage
Note 4
Δλ
VF
IR
2.25
2.7
IF = 20mA
μ
A
Reverse Current
100
VR = 5V
Capacitance
C
40
pF
VF = 0 , f = 1MHz
NOTE: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
θ
2. 1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. Iv classification code is marked on each packing bag.
λ
4. The dominant wavelength, d is derived from the CIE chromaticity diagram and represents the
single wavelength which defines the color of the device.
±
5. The Iv guarantee should be added 15% .
Part No. : LTL2R3SEK-1
BNS-OD-C131/A4
Page :
3
of
10