ꢀꢀꢁ ꢂ ꢃ ꢄ ꢅ ꢆ ꢇ ꢀ ꢀ ꢄ ꢁ ꢄ ꢈ ꢃ ꢉ ꢆ ꢇ ꢂ ꢈ ꢊ ꢋ ꢀ ꢂ ꢇ ꢈ ꢌ
ꢀ ꢁ ꢂ ꢃ ꢄ ꢁ ꢅ ꢆ ꢇ ꢂ ꢈ ꢇ ꢉ ꢊ ꢅ ꢄ ꢋ ꢌ ꢍ ꢇ ꢌ ꢍ ꢎ ꢆ
ꢀ
Electrical / Optical Characteristics at TA=25 (F Series)
Parameter
Symbol Part No. (LTL)
Min.
Typ.
Max.
Unit
Test Condition
1CHJDDNN
1CHJRDNN
3.0
3.0
3.0
3.0
3.0
3.0
3.0
5.0
5.6
7.2
7.2
7.2
7.2
7.2
IF = 2mA
Note 1
1CHJEDNN
Luminous
Iv
mcd
1CHJFDNN
1CHJYDNN
1CHJSDNN
1CHJGDNN
Intensity
Note 2
Viewing Angle
2 1/2
60
deg
nm
Note 3 (Fig.5)
θ
1CHJDDNN
1CHJRDNN
1CHJEDNN
1CHJFDNN
1CHJYDNN
1CHJSDNN
1CHJGDNN
1CHJDDNN
1CHJRDNN
1CHJEDNN
1CHJFDNN
1CHJYDNN
1CHJSDNN
1CHJGDNN
1CHJDDNN
1CHJRDNN
1CHJEDNN
1CHJFDNN
1CHJYDNN
1CHJSDNN
1CHJGDNN
1CHJDDNN
1CHJRDNN
1CHJEDNN
1CHJFDNN
1CHJYDNN
1CHJSDNN
1CHJGDNN
650
639
632
611
595
588
575
639
632
624
605
592
587
572
20
Peak Emission
Wavelength
Measurement
@ peak (Fig.1)
P
λ
Dominant
d
λ
nm
nm
V
Note 5
Wavelength
20
20
Spectral Line
Half-Width
∆λ
17
15
15
15
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.4
2.3
2.4
2.4
2.4
2.4
2.4
Forward Voltage
VF
IF = 2mA
Reverse Current
Capacitance
IR
C
100
A
µ
VR = 5V
pF
VF = 0, f = 1 MHz
40
NOTES:
1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE eye-response curve.
2. Luminous intensity rank classified products support two ranks.
3. θ 1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
4. Iv classification code is marked on each packing bag.
5. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents the single wavelength which
defines the color of the device.