LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Electrical / Optical Characteristics at T
A
=25
℃
Parameter
Symbol
Min.
Typ.
Max.
Unit
Test Condition
I
F
= 10mA
Note 1,4
Note 2 (Fig.6)
Measurement
@Peak (Fig.1)
Note 3
Luminous Intensity
I
V
2θ
1/2
λ
P
λ
d
Δλ
19
60
200
mcd
Viewing Angle
60
deg
Peak Emission Wavelength
635
nm
Dominant Wavelength
615
625
632
nm
Spectral Line Half-Width
40
nm
Forward Voltage
V
F
2.0
2.6
V
μA
I
F
= 20mA
Reverse Current
I
R
100
V
R
= 5V
Capacitance
C
20
pF
V
F
= 0 , f = 1MHz
Note: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
(Commission International De L'Eclairage) eye-response curve.
2.
θ
1/2
is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. The dominant wavelength,
λ
d
is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
4. The Iv guarantee should be added
±15%
.
Part No. : LTL-10223W-132A
BNS-OD-C131/A4
Page :
3
of
11