LITE-ON TECHNOLOGY CORPORATION
P r o p e r t y o f L i t e - O n O n l y
℃
Electrical / Optical Characteristics at T =25
A
Parameter
Luminous Intensity
Viewing Angle
Symbol
IV
Min.
12.6
Typ.
Max.
Unit
mcd
deg
nm
nm
nm
V
Test Condition
IF = 10mA
Note 1,4
40
60
θ
2
1/2
Note 2 (Fig.6)
Measurement
@Peak (Fig.1)
λP
λd
Peak Emission Wavelength
Dominant Wavelength
Spectral Line Half-Width
Forward Voltage
565
573
568
578
Note 3
Δλ
VF
IR
30
2.1
2.6
IF = 20mA
μ
A
Reverse Current
100
VR = 5V
Capacitance
C
35
pF
VF = 0 , f = 1MHz
Note: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
(Commission International De L'Eclairage) eye-response curve.
θ
2. 1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
λd is derived from the CIE chromaticity diagram and represents the single
3. The dominant wavelength,
wavelength which defines the color of the device.
±
4. The Iv guarantee should be added 15%.
Part No. : LTL-10233W-EA
BNS-OD-C131/A4
Page :
3
of
8