Photocouplers
CNY17-1-V thru CNY17-4-V SERIES
4.4 PARTIAL DISCHARGE TEST METHOD
Method (A) for type testing and random testing.
V
VINTIAL
Vpr
t1, t2
t3, t4
= 1 to 10s
= 1s
VIORM
tp (Partial Discharge Measuring Time)= 60s
tb
= 62s
= 10s
tini
t
tp
tb
t3
t4
t1
tini
t2
Method (B) for routine testing.
V
Vpr
t3, t4
= 0.1s
tp (Partial Discharge Measuring Time)= 1s
tb = 1.2s
VIORM
t
tp
tb
t3
t4
The partial discharge level shall not exceed 5 pc during the partial discharge measuring time interval tp under the test
conditions shown above.
Part No : CNY17-1-V thru CNY17-4-V
SERIES
BNC-OD-C131/A4
9/14