Photocouplers
CNY17-1-V thru CNY17-4-V SERIES
4.3 ISOLATION SPECIFICATION ACCORDING TO VDE
Parameter
Symbol
Conditions
Rating
Unit
Remark
Class of environmental test
Pollution
-
-
DIN IEC68
55/100/21
2
-
-
DIN VDE0110
-
Maximum Operating
Isolation Voltage
VIORM
850
VPEAK
Partial Discharge Test
Voltage (Between Input
and Output)
Diagram 1
Diagram 2
tp=60s, qc<5pC
1275
VPEAK
Refer to the Diagram
1, 2
Vpr
tp=1s, qc<5pC
tINI = 10s
1594
6000
VPEAK
Maximum Over-voltage
Safety Maximum Ratings
1) Case Temperature
2) Input Current
VINITIAL
VPEAK
Tsi
Isi
IF = 0, Pc = 0
Pc=0
175
400
oC
Refer to the
Figure 1, 3
mA
3) Electric Power (Output or Total
Power Issipation)
Psi
-
700
mW
Ta=Tsi
MIN.109
Isolation Resistance
(Test Voltage Between
Input and Output : DC500V)
RISO
Ta=Topr(MAX.)
Ta=25 oC
MIN.1011
MIN.1012
Precautions in performing isolation test
* Partial discharge test methods shall be the ones according to the specifications of DIN EN 60747-5-5
* Please don't carry out isolation test (Viso) over VINITIAL ,This product deteriorates
isolation characteristics by partial discharge due to applying high voltage
(ex. VINITIAL ). And there is possibility that this product occurs partial discharge in
operating isolation voltage (VIORM
)
Part No : CNY17-1-V thru CNY17-4-V
SERIES
BNC-OD-C131/A4
8/14