LTC2996
elecTrical characTerisTics The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C, VCC = 3.3V, unless otherwise noted.
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
3.5
4
MAX
UNITS
ms
T
Temperature Update Interval
5
CONV
K
V
PTAT
V
PTAT
Slope
mV/K
mV
Ideality Factor η = 1.004
T
Load Regulation
I
= 200μA
1.5
LOAD
T
T
Internal Temperature Accuracy
Remote Temperature Error, η = 1.004
Temperature Noise
0.5
0.5
0.5
1
2
3
°C
°C
°C
INT
l
l
LTC2996C, LTC2996I
LTC2996H
0°C to 85°C (Notes 4, 5)
–40°C to 0°C (Notes 4, 5)
85°C to 125°C (Notes 4, 5)
0.25
0.25
0.25
1
1.5
1.5
°C
°C
°C
RMT
0.15
0.01
°C
RMS
°C
RMS
/√Hz
°C/V
°C
l
l
T
T
Temperature Error vs Supply
0.5
1
VCC
RS
Series Resistance Cancellation Error
R
= 100Ω
0.25
SERIES
Temperature Monitoring
l
l
l
T
VTH, VTL Offset
–3
2
–1
5
1
°C
°C
nA
OFF
∆T
OT, UT Temperature Hysteresis
VTH, VTL, Input Current
10
20
HYST
I
IN
Digital Outputs
l
l
V
V
High Level Output Voltage, OT, UT
Low Level Output Voltage, OT, UT
I = –0.5μA
I = 3mA
V
CC
– 1.2
V
V
OH
OL
0.4
+
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 3: If voltage on pin D exceeds the diode select threshold the
LTC2996 uses the internal diode sensor.
Note 4: Remote diode temperature, not LTC2996 temperature.
Note 5: Guaranteed by design and test correlation.
Note 2: All currents into pins are positive; all voltages are referenced to
GND unless otherwise noted.
2996f