LND-SP64HV
Ordering Information
Package Options
80-Lead PQFP
20.00x14.00mm
body
3.40mm
height (max)
0.80mm
pitch
Pin Configuration
Device
LND-SP64HV
LND-SP64HV-PG-G
-G indicates package is ROHS compliant (‘Green’)
Absolute Maximum Ratings
Parameter
Supply voltage, V
DD
Output voltage, V
PP
Logic input levels
Ground current
1
Continuous total power dissipation
2
Operating temperature range
Storage temperature range
Lead temperature
3
Value
-0.5V to +5.5V
-0.5V to +90V
-0.3V to V
DD
+0.3V
1.5A
1200mW
-40°C to +85°C
-65°C to 150°C
260°C
80-Lead PQFP (PG)
(top view)
Absolute Maximum Ratings are those values beyond which damage to
the device may occur. Functional operation under these conditions is not
implied. Continuous operation of the device at the absolute rating level
may affect device reliability. All voltages are referenced to device
ground.
.
Notes:
1.
Limited by the total power dissipated in the package
2.
For operation above 25°C ambient derate linearly to maximum
3.
operating temperature at 20mW/°C.
1.6mm(1/16inch) from case for 10 seconds
Recommended Operating conditions
Sym
V
DD
V
PP
V
IH
V
IL
f
CLK
T
A
Parameter
Logic supply voltage
Output voltage
High-level input voltage
Low-level input voltage
Clock frequency per register
Operating free-air temperature
Min
4.5
8.0
V
DD
-0.5V
0
-40
Max
5.5
90
0.5
8.0
+85
Units
V
V
V
V
MHz
°C
Notes:
Power-up sequence should be the following:
1. Apply ground.
2. Apply V
DD
.
3. Set all inputs (D
IN
, CLK, Enable, etc.) to a known state.
4. Apply V
PP
.
5. The V
PP
should not drop below V
DD
or float during operation.
Power-down sequence should be the reverse of the above
Linear Dimensions, Inc.
445 East Ohio Street, Chicago IL 60611 USA
tel 312.404.9283
fax 312.321.1830