 浏览型号LTC2970CUFD#TR的Datasheet PDF文件第50页浏览型号LTC2970CUFD#TR的Datasheet PDF文件第51页浏览型号LTC2970CUFD#TR的Datasheet PDF文件第52页浏览型号LTC2970CUFD#TR的Datasheet PDF文件第53页浏览型号LTC2970CUFD#TR的Datasheet PDF文件第55页浏览型号LTC2970CUFD#TR的Datasheet PDF文件第56页浏览型号LTC2970CUFD#TR的Datasheet PDF文件第57页浏览型号LTC2970CUFD#TR的Datasheet PDF文件第58页  
LTC2978  
PMBus COMMAND DESCRIPTION  
MFR_VOUT_MIN  
This command returns the minimum ADC measured value of the channel’s output voltage. This register is reset to  
±xFFFF (7.999) when the LTC2978 emerges from power-on reset or when a CLEAR_FAULTS command is executed.  
When odd channels are configured to measure current, this command is not supported. Updates are disabled when  
undervoltage detection is disabled.  
MFR_VOUT_MIN Data Contents  
BIT(S)  
SYMBOL  
OPERATION  
b[1ꢀ:±]  
Mfr_vout_min  
The data uses the L16 format.  
Units: V.  
MFR_VIN_MIN  
This command returns the minimum ADC measured value of the input voltage. This register is reset to ±x7BFF  
2ꢀ  
(approximately 2 ) when the LTC2978 emerges from power-on reset or when a CLEAR_FAULTS command is executed.  
Updates are disabled when unit is off for insufficient input voltage.  
MFR_VIN_MIN Data Contents  
BIT(S)  
SYMBOL  
OPERATION  
b[1ꢀ:±]  
Mfr_vin_min  
The data uses the L11 format.  
Units: V.  
MFR_TEMPERATURE_MIN  
This command returns the minimum ADC measured value of junction temperature in °C as determined by the LTC2978’s  
2ꢀ  
internal temperature sensor. This register is reset to ±x7BFF (approximately 2 ) when the LTC2978 emerges from  
power-on reset or when a CLEAR_FAULTS command is executed.  
MFR_TEMPERATURE_MIN Data Contents  
BIT(S) SYMBOL  
OPERATION  
b[1ꢀ:±] Mfr_temperature_min The data uses the L11 format.  
Units: °C.  
FAULT LOG OPERATION  
A conceptual diagram of the fault log is shown in Figure 13. The fault log provides black box capability to the LTC2978.  
During normal operation, the contents of the status registers, the output voltage/current readings, temperature readings  
as well as peak and min values of these quantities are stored in a continuously updated buffer in RAM. You can think  
of the operation as being similar to a strip chart recorder. When a fault occurs, the contents are written into EEPROM  
for nonvolatile storage. The EEPROM fault log is then locked. The part can be powered down with the fault log being  
available for reading at a later time.  