OPERATION  
Undervoltage Lockout (UVLO)  
falls 100mV below the float voltage (which corresponds  
to 80% to 90% battery capacity), a new charge cycle is  
initiated and a 2.25 hour timer begins. This ensures that  
the battery is kept at, or near, a fully charged condition and  
eliminates the need for periodic charge cycle initiations.  
TheCHRGoutputassumesastrongpull-downstateduring  
recharge cycles until C/10 is reached when it transitions  
to a high impendance state.  
Aninternalundervoltagelockoutcircuitmonitorstheinput  
voltageandkeepsthechargerinundervoltagelockoutuntil  
V
rises above 3.6V and approximately 80mV above the  
CC  
BAT pin voltage. The 3.6V UVLO circuit has a built-in hys-  
teresisofapproximately0.6Vandtheautomaticshutdown  
thresholdhasabuilt-inhysteresisofapproximately50mV.  
Duringundervoltagelockoutconditions,maximumbattery  
draincurrentis4μAandmaximumsupplycurrentis11μA.  
Trickle Charge and Defective Battery Detection  
Shutdown Mode  
At the beginning of a charge cycle, if the battery voltage  
is low (below 2.9V), the charger goes into trickle charge,  
reducing the charge current to 10% of the full-scale cur-  
rent (Note: The LTC4065LX has full charge current at  
low-battery voltage). If the low-battery voltage persists  
for one quarter of the total time (1.125 hour), the battery  
is assumed to be defective, the charge cycle is terminated  
and the CHRG pin output pulses at a frequency of 2Hz with  
a 75% duty cycle. If for any reason the battery voltage  
rises above 2.9V, the charge cycle will be restarted. To  
restart the charge cycle (i.e., when the defective battery  
is replaced with a discharged battery), simply remove the  
input voltage and reapply it or temporarily pull the EN pin  
above the shutdown threshold.  
The LTC4065L can be disabled by pulling the EN pin  
above the shutdown threshold (approximately 0.82V).  
In shutdown mode, the battery drain current is reduced  
to less than 1μA and the supply current to about 20μA.  
Timer and Recharge  
The LTC4065L has an internal termination timer that  
starts when an input voltage greater than the undervolt-  
age lockout threshold is applied to VCC, or when leaving  
shutdown the battery voltage is less than the recharge  
threshold.  
At power-up or when exiting shutdown, if the battery volt-  
age is less than the recharge threshold, the charge time is  
set to 4.5 hours. If the battery voltage is greater than the  
rechargethresholdatpower-uporwhenexitingshutdown,  
the timer will not start and charging is prevented since the  
battery is at or near full capacity.  
CHRG Status Output Pin  
The charge status indicator pin has three states: pull-  
down, pulse at 2Hz (see Trickle Charge and Defective  
Battery Detection) and high impedance. The pull-down  
state indicates that the LTC4065L is in a charge cycle. A  
high impedance state indicates that the charge current  
has dropped below 10% of the full-scale current or the  
LTC4065L is disabled. Figure 2 shows the CHRG status  
under various conditions.  
Once the charge cycle terminates, the LTC4065L continu-  
ously monitors the BAT pin voltage using a comparator  
with a 2ms filter time. When the average battery voltage  
4065lfb  