欢迎访问ic37.com |
会员登录 免费注册
发布采购

LT1101ACH 参数 Datasheet PDF下载

LT1101ACH图片预览
型号: LT1101ACH
PDF下载: 下载PDF文件 查看货源
内容描述: 高精度,微功耗,单电源仪表放大器(固定增益= 10或100 ) [Precision, Micropower, Single Supply Instrumentation Amplifier (Fixed Gain = 10 or 100)]
分类和应用: 仪表放大器
文件页数/大小: 16 页 / 234 K
品牌: Linear Systems [ Linear Systems ]
 浏览型号LT1101ACH的Datasheet PDF文件第7页浏览型号LT1101ACH的Datasheet PDF文件第8页浏览型号LT1101ACH的Datasheet PDF文件第9页浏览型号LT1101ACH的Datasheet PDF文件第10页浏览型号LT1101ACH的Datasheet PDF文件第12页浏览型号LT1101ACH的Datasheet PDF文件第13页浏览型号LT1101ACH的Datasheet PDF文件第14页浏览型号LT1101ACH的Datasheet PDF文件第15页  
LT1101  
U W  
TYPICAL PERFOR A CE CHARACTERISTICS  
Single Supply: Minimum  
Common Mode Voltage vs  
Output Voltage  
Single Supply: Minimum Output  
Voltage vs Common Mode  
Voltage  
Minimum Supply Voltage vs  
Temperature  
2.5  
2.0  
1.5  
1.0  
0.5  
0
120  
100  
10  
9
+
V
= 0V  
V
V
= 1.8V TO 15V  
= OV  
125°C  
25°C  
G = 10  
NO LOAD  
8
7
MINIMUM  
SUPPLY VOLTAGE  
25°C  
OUTPUT SWING  
80  
60  
40  
20  
0
25°C  
–55°C  
125°C  
AT MINIMUM SUPPLY  
6
5
4
3
2
1
0
–55°C  
125°C  
25°C  
G = 100  
–55°C  
125°C  
–55°C  
COMMON-MODE RANGE  
AT MINIMUM SUPPLY  
G = 10  
G = 100  
4
+
V
V
= 1.8V TO 15V  
= OV  
0
6
8
10  
12  
125  
2
0
10 20 30 40 50 60 70 80 90 100  
MINIMUM OUTPUT VOLTAGE (mV)  
–50  
50  
TEMPERATURE (°C)  
100  
–25  
0
25  
75  
OUTPUT VOLTAGE (V)  
LT1101 • TPC21  
LT1101 • TPC23  
LT1101 • TPC22  
W U U  
U
APPLICATIO S I FOR ATIO  
Single Supply Applications  
When the output is high and input common mode is low,  
the output of amplifier A has to sink current coming from  
the output of amplifier B. Since amplifier A is effectively in  
unity gain, its input is limited by its output.  
The LT1101 is the first instrumentation amplifier which is  
fully specified for single supply operation, (i.e. when the  
negative supply is 0V). Both the input common mode  
range and the output swing are within a few millivolts of  
ground.  
Common Mode Rejection vs Frequency  
The common mode rejection ratio (CMRR) of the LT1101  
starts to roll off at a relatively low frequency. However, as  
shown on the Common Mode Rejection Ratio vs Fre-  
quency plot, CMRR can be enhanced significantly by  
connecting an 82pF capacitor between pins 1 and 2. This  
improvement is only available in the gain 100 configura-  
tion, and it is in excess of 30dB at 60Hz.  
Probably the most common application for instrumenta-  
tion amplifiers is amplifying a differential signal from a  
transducer or sensor resistance bridge. All competitive  
instrumentation amplifiers have a minimum required  
common mode voltage which is 3V to 5V above the  
negative supply. This means that the voltage across the  
bridgehastobe6Vto10Vordualsupplieshavetobeused  
(i.e., micropower) single battery usage is not attainable on  
competitive devices.  
Offset Nulling  
The LT1101 is not equipped with dedicated offset null  
terminals. In many bridge transducer or sensor applica-  
tions, calibrating the bridge simultaneously eliminates the  
instrumentation amplifier’s offset as a source of error. For  
example, in the Micropower Remote Temperature Sensor  
Application shown, one adjustment removes the offset  
errors due to the temperature sensor, voltage reference  
and the LT1101.  
The minimum output voltage obtainable on the LT1101 is  
a function of the input common mode voltage. When the  
common mode voltage is high and the output is low,  
current will flow from the output of amplifier A into the  
output of amplifier B. See the Minimum Output Voltage vs  
Common Mode Voltage plot.  
Similarly, the Single Supply Minimum Common Mode  
Voltage vs Output Voltage plot specifies the expected  
common mode range.  
1101fa  
11