 浏览型号QBVW025A0B641HZ的Datasheet PDF文件第4页浏览型号QBVW025A0B641HZ的Datasheet PDF文件第5页浏览型号QBVW025A0B641HZ的Datasheet PDF文件第6页浏览型号QBVW025A0B641HZ的Datasheet PDF文件第7页浏览型号QBVW025A0B641HZ的Datasheet PDF文件第9页浏览型号QBVW025A0B641HZ的Datasheet PDF文件第10页浏览型号QBVW025A0B641HZ的Datasheet PDF文件第11页浏览型号QBVW025A0B641HZ的Datasheet PDF文件第12页  
Data Sheet  
GE  
QBVW025A0B Barracuda™ Series; DC-DC Converter Power Modules  
36-75Vdc Input; 12.0Vdc, 25.0A, 300W Output  
output voltage to rise above the limit in the Specifications  
Table, the module will shut down and remain latched off. The  
Feature Descriptions  
Overcurrent Protection  
overvoltage latch is reset by either cycling the input power, or  
by toggling the on/off pin for one second. If the output  
overvoltage condition still exists when the module restarts, it  
will shut down again. This operation will continue indefinitely  
until the overvoltage condition is corrected.  
To provide protection in a fault output overload condition, the  
module is equipped with internal current-limiting circuitry and  
can endure current limiting continuously. If the overcurrent  
condition causes the output voltage to fall greater than 4.0V  
from Vo,set, the module will shut down and remain latched off.  
The overcurrent latch is reset by either cycling the input power  
or by toggling the on/off pin for one second. If the output  
overload condition still exists when the module restarts, it will  
shut down again. This operation will continue indefinitely until  
the overcurrent condition is corrected.  
A factory configured auto-restart option (with overcurrent and  
overvoltage auto-restart managed as a group) is also available.  
An auto-restart feature continually attempts to restore the  
operation until fault condition is cleared.  
Overtemperature Protection  
These modules feature an overtemperature protection circuit  
to safeguard against thermal damage. The circuit shuts down  
the module when the maximum device reference temperature  
is exceeded. The module will automatically restart once the  
reference temperature cools by ~25°C.  
A factory configured auto-restart option (with overcurrent and  
overvoltage auto-restart managed as a group) is also available.  
An auto-restart feature continually attempts to restore the  
operation until fault condition is cleared.  
Remote On/Off  
Input Under/Over voltage Lockout  
The module contains a standard on/off control circuit reference  
to the VIN(-) terminal. Two factory configured remote on/off  
logic options are available. Positive logic remote on/off turns  
the module on during a logic-high voltage on the ON/OFF pin,  
and off during a logic low. Negative logic remote on/off turns  
the module off during a logic high, and on during a logic low.  
Negative logic, device code suffix "1," is the factory-preferred  
configuration. The On/Off circuit is powered from an internal  
bias supply, derived from the input voltage terminals. To turn  
the power module on and off, the user must supply a switch to  
control the voltage between the On/Off terminal and the VIN(-)  
terminal (Von/off). The switch can be an open collector or  
equivalent (see Figure 14). A logic low is Von/off = -0.3V to 0.8V.  
The typical Ion/off during a logic low (Vin=48V, On/Off  
At input voltages above or below the input under/over voltage  
lockout limits, module operation is disabled. The module will  
begin to operate when the input voltage level changes to within  
the under and overvoltage lockout limits.  
Load Sharing  
For higher power requirements, the QBVW025A0 power module  
offers an optional feature for parallel operation (-P Option  
code). This feature provides a precise forced output voltage  
load regulation droop characteristic. The output set point and  
droop slope are factory calibrated to insure optimum matching  
of multiple modules’ load regulation characteristics. To  
implement load sharing, the following requirements should be  
followed:  
Terminal=0.3V) is 147µA. The switch should maintain a logic-  
low voltage while sinking 310µA. During a logic high, the  
maximum Von/off generated by the power module is 8.2V. The  
. The VOUT(+) and VOUT(-) pins of all parallel modules must be  
connected together. Balance the trace resistance for each  
module’s path to the output power planes, to insure best  
load sharing and operating temperature balance.  
maximum allowable leakage current of the switch at Von/off  
2.0V is TBDµA. If using an external voltage source, the  
=
maximum voltage Von/off on the pin is 14.5V with respect to the  
VIN(-) terminal.  
.
.
VIN must remain between 40Vdc and 75Vdc for droop sharing  
to be functional.  
If not using the remote on/off feature, perform one of the  
following to turn the unit on:  
These modules contain means to block reverse current flow  
upon start-up, when output voltage is present from other  
parallel modules, thus eliminating the requirement for  
external output ORing devices. Modules with the –P option  
will self determine the presence of voltage on the output  
from other operating modules, and automatically increase  
its Turn On delay, Tdelay, as specified in the Feature  
Specifications Table.  
For negative logic, short ON/OFF pin to VIN(-).  
For positive logic: leave ON/OFF pin open.  
.
When parallel modules startup into a pre-biased output, e.g.  
partially discharged output capacitance, the Trise is  
automatically increased, as specified in the Feature  
Specifications Table, to insure graceful startup.  
Insure that the load is <50% IO,MAX (for a single module) until  
all parallel modules have started (load full start > module  
Tdelay time max + Trise time).  
If fault tolerance is desired in parallel applications, output  
ORing devices should be used to prevent a single module  
failure from collapsing the load bus.  
.
.
Figure 14. Remote On/Off Implementation.  
Output Overvoltage Protection  
The module contains circuitry to detect and respond to output  
overvoltage conditions. If the overvoltage condition causes the  
May 9, 2013  
©2012 General Electric Company. All rights reserved.  
Page 8  